MétaCan
Menu
Back to cohort
Record W3158423698 · doi:10.1101/2021.04.25.441198

Towards community-driven metadata standards for light microscopy: tiered specifications extending the OME model

2021· preprint· en· W3158423698 on OpenAlexaff
Mathias Hammer, Maximiliaan Huisman, Alex Rigano, Ulrike Boehm, James J. Chambers, Nathalie Gaudreault, Alison J. North, Jaime A. Pimentel, Damir Sudar, Peter Bajcsy, Claire M. Brown, Alexander D. Corbett, Orestis Faklaris, Judith Lacoste, Alex Laude, Glyn Nelson, Farzin Farzam, Carlas Smith, David Grünwald, Caterina Strambio‐De‐Castillia

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2021
Typepreprint
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicCell Image Analysis Techniques
Canadian institutionsMcGill University
FundersDeutsche ForschungsgemeinschaftNederlandse Organisatie voor Wetenschappelijk OnderzoekChan Zuckerberg InitiativeSilicon Valley Community FoundationNational Cancer InstituteNational Institutes of HealthNational Science Foundation
KeywordsMetadataComputer scienceMicroscopeData qualityMicroscopyQuality (philosophy)Control (management)Data scienceData miningArtificial intelligenceWorld Wide WebEngineeringOptics

Abstract

fetched live from OpenAlex

1 - ABSTRACT Digital light microscopy provides powerful tools for quantitatively probing the real-time dynamics of subcellular structures. While the power of modern microscopy techniques is undeniable, rigorous record-keeping and quality control are required to ensure that imaging data may be properly interpreted ( quality ), reproduced ( reproducibility ), and used to extract reliable information and scientific knowledge which can be shared for further analysis ( value ). Keeping notes on microscopy experiments and quality control procedures ought to be straightforward, as the microscope is a machine whose components are defined and the performance measurable. Nevertheless, to this date, no universally adopted community-driven specifications exist that delineate the required information about the microscope hardware and acquisition settings (i.e., microscopy “data provenance” metadata) and the minimally accepted calibration metrics (i.e., microscopy quality control metadata) that should be automatically recorded by both commercial microscope manufacturers and customized microscope developers. In the absence of agreed guidelines, it is inherently difficult for scientists to create comprehensive records of imaging experiments and ensure the quality of resulting image data or for manufacturers to incorporate standardized reporting and performance metrics. To add to the confusion, microscopy experiments vary greatly in aim and complexity, ranging from purely descriptive work to complex, quantitative and even sub-resolution studies that require more detailed reporting and quality control measures. To solve this problem, the 4D N ucleome Initiative (4DN) ( 1, 2 ) Imaging Standards Working Group (IWG), working in conjunction with the B io I maging N orth A merica (BINA) Quality Control and Data Management Working Group (QC-DM-WG) ( 3 ), here propose light Microscopy Metadata specifications that scale with experimental intent and with the complexity of the instrumentation and analytical requirements. They consist of a revision of the Core of the Open Microscopy Environment (OME) Data Model, which forms the basis for the widely adopted Bio-Formats library ( 4 – 6 ), accompanied by a suite of three extensions, each with three tiers, allowing the classification of imaging experiments into levels of increasing imaging and analytical complexity ( 7, 8 ). Hence these specifications not only provide an OME-based comprehensive set of metadata elements that should be recorded, but they also specify which subset of the full list should be recorded for a given experimental tier. In order to evaluate the extent of community interest, an extensive outreach effort was conducted to present the proposed metadata specifications to members of several core-facilities and international bioimaging initiatives including the E uropean L ight M icroscopy I nitiative (ELMI), G lobal B io I maging (GBI), and E uropean M olecular B iology L aboratory (EMBL) - E uropean B ioinformatics I nstitute (EBI). Consequently, close ties were established between our endeavour and the undertakings of the recently established QUA lity Assessment and REP roducibility for Instruments and Images in Li ght Mi croscopy global community initiative ( 9 ). As a result this flexible 4D N - B INA- O ME (NBO namespace) framework ( 7, 8 ) represents a turning point towards achieving community-driven Microscopy Metadata standards that will increase data fidelity, improve repeatability and reproducibility, ease future analysis and facilitate the verifiable comparison of different datasets, experimental setups, and assays, and it demonstrates the method for future extensions. Such universally accepted microscopy standards would serve a similar purpose as the Encode guidelines successfully adopted by the genomic community ( 10, 11 ). The intention of this proposal is therefore to encourage participation, critiques and contributions from the entire imaging community and all stakeholders, including research and imaging scientists, facility personnel, instrument manufacturers, software developers, standards organizations, scientific publishers, and funders.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.506
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0020.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.289
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)Same topicCell Image Analysis TechniquesFrench-language works237,207