Evaluation of the Privacy Risks of Personal Health Identifiers and Quasi-Identifiers in a Distributed Research Network: Development and Validation Study
Bibliographic record
Abstract
BACKGROUND: Privacy should be protected in medical data that include patient information. A distributed research network (DRN) is one of the challenges in privacy protection and in the encouragement of multi-institutional clinical research. A DRN standardizes multi-institutional data into a common structure and terminology called a common data model (CDM), and it only shares analysis results. It is necessary to measure how a DRN protects patient information privacy even without sharing data in practice. OBJECTIVE: This study aimed to quantify the privacy risk of a DRN by comparing different deidentification levels focusing on personal health identifiers (PHIs) and quasi-identifiers (QIs). METHODS: We detected PHIs and QIs in an Observational Medical Outcomes Partnership (OMOP) CDM as threatening privacy, based on 18 Health Insurance Portability and Accountability Act of 1996 (HIPPA) identifiers and previous studies. To compare the privacy risk according to the different privacy policies, we generated limited and safe harbor data sets based on 16 PHIs and 12 QIs as threatening privacy from the Synthetic Public Use File 5 Percent (SynPUF5PCT) data set, which is a public data set of the OMOP CDM. With minimum cell size and equivalence class methods, we measured the privacy risk reduction with a trust differential gap obtained by comparing the two data sets. We also measured the gap in randomly sampled records from the two data sets to adjust the number of PHI or QI records. RESULTS: The gaps averaged 31.448% and 73.798% for PHIs and QIs, respectively, with a minimum cell size of one, which represents a unique record in a data set. Among PHIs, the national provider identifier had the highest gap of 71.236% (71.244% and 0.007% in the limited and safe harbor data sets, respectively). The maximum size of the equivalence class, which has the largest size of an indistinguishable set of records, averaged 771. In 1000 random samples of PHIs, Device_exposure_start_date had the highest gap of 33.730% (87.705% and 53.975% in the data sets). Among QIs, Death had the highest gap of 99.212% (99.997% and 0.784% in the data sets). In 1000, 10,000, and 100,000 random samples of QIs, Device_treatment had the highest gaps of 12.980% (99.980% and 87.000% in the data sets), 60.118% (99.831% and 39.713%), and 93.597% (98.805% and 5.207%), respectively, and in 1 million random samples, Death had the highest gap of 99.063% (99.998% and 0.934% in the data sets). CONCLUSIONS: In this study, we verified and quantified the privacy risk of PHIs and QIs in the DRN. Although this study used limited PHIs and QIs for verification, the privacy limitations found in this study could be used as a quality measurement index for deidentification of multi-institutional collaboration research, thereby increasing DRN safety.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.191 | 0.377 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.002 | 0.002 |
| Science and technology studies | 0.002 | 0.005 |
| Scholarly communication | 0.003 | 0.006 |
| Open science | 0.004 | 0.005 |
| Research integrity | 0.003 | 0.003 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; the direct Gemma label and the distilled Codex classifier agree on what is shown here.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".