MétaCan
Menu
Back to cohort
Record W3168949176

Development of a Cardiac and Respiratory Phantom (CARP) for use in Radiosurgery Dosimetry

2021· article· en· W3168949176 on OpenAlexaff
Don Ta, Anthony T.�C. Chan, Steven Thomas

Bibliographic record

VenueCMBES Proceedings · 2021
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of British ColumbiaBC Cancer Agency
Fundersnot available
KeywordsImaging phantomRadiosurgeryMedicineDosimetryCyberknifeRadiation therapyRespiratory monitoringRespiratory systemNuclear medicineRadiologyInternal medicine
DOInot available

Abstract

fetched live from OpenAlex

Cardiac Radiosurgery is one of the newest modalities for management of ventricular tachyarrhythmia (VT). It precisely targets radiation to the heart using a high-dose single fraction treatment to scar or destroy cardiac tissue that is allowing irregular electrical signals. Patients often have ICDs with leads that have metal components close to the targets for treatment within the heart. These ICD leads are easily distinguished in kilovolt imaging avoiding any need for additional invasive surgery to implant fiducial markers within the patient. Although respiratory motion management techniques are well established in the radiotherapy setting, there are currently no commercially available systems that evaluate the effects of cardiac motion on respiratory tracking. The cardiac and respiratory phantom (CARP) is designed to mimic cardiac-coupled respiratory motion for use in determining the ability of a medical linear accelerator to track an ICD lead as a motion surrogate. The phantom displaces a platform, which can house ICD leads and dosimeters, in the cranio-caudal and medial-lateral directions. The cardiac and respiratory rates and displacements are user controlled through a computer which is coupled to the phantom by an Arduino. The CARP can achieve up to 150 breaths and 250 cardiac beats per minute to within a 1% error, for standard displacements. The total cardiac and respiratory travel ranges achieved are 3.5 and 4cm, respectively. The CARP can successfully be used as a quality assurance tool in the setting of tracked radiosurgery for cardiac targets.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.288
Threshold uncertainty score0.320

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.327
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueCMBES ProceedingsSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207