MétaCan
Menu
Back to cohort
Record W3173505304

A Diffuse Reflectance Spectroscopy Instrument for use in the Optical Biopsy of Brain Tumour Margins

2016· dissertation· en· W3173505304 on OpenAlexfundno aff
Derek J. Cappon

Bibliographic record

VenueMacSphere (McMaster University) · 2016
Typedissertation
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsnot available
FundersOntario Centres of Excellence
KeywordsDiffuse reflectance infrared fourier transformReflectivityDiffuse reflectionSpectroscopyOpticsMaterials scienceMedicinePathologyChemistryPhysicsAstronomy
DOInot available

Abstract

fetched live from OpenAlex

Optical biopsy is a medical technique that uses light to perform non-invasive analysis of tissue in-situ. This technology has many applications in the medical profession, opening up exciting new possibilities for surgical guidance and diagnosis of malignancies and other conditions. Optical biopsy allows a medical professional to perform near instantaneous, real time analysis of tissue composition without the need to physically remove tissue from the body, as required in traditional biopsy. A technique frequently used for this purpose is diffuse reflectance spectroscopy (DRS): collection and analysis of the spectrum of light reflected from a material. Another technique frequently used for optical biopsy is laser induced fluorescence spectroscopy (LIFS): analysis of the fluorescence spectrum returned by a material when illuminated at a specific wavelength. This thesis discusses the design and construction of a spatially resolved DRS system intended for use in a dual modality DRS and time resolved LIFS optical biopsy instrument for clinical analysis of brain tissue. This instrument is specifically intended for use in the surgical removal of malignant gliomas: infiltrating tumours associated with a poor patient prognosis. Theoretical simulation based studies were used to optimize the design of a compact, dual modality fibre optic probe for use in the system and a novel algorithm was developed to allow recovery of the optical properties of tissue from reflectance spectra obtained with this probe. This probe was manufactured and a corresponding spectrometer based system was created for the acquisition of diffuse reflectance spectra. Components were designed to allow sterilization and thus clinical use in an operating room environment. A laboratory trial of this system demonstrated its range and ability to recover the optical properties of lipid emulsion optical phantoms.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.007
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0070.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.280
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMacSphere (McMaster University)Same topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207