Diagnostic Efficacy of a Single-Lead Ambulatory 14-Day ECG Monitor in Symptomatic Children
Bibliographic record
Abstract
BACKGROUND: The CardioSTAT is a single-lead ambulatory electrocardiography monitor that has been validated for use in adult patients. Recording is made through 2 electrodes positioned in a lead-I configuration, and the device allows monitoring for 2, 7, or 14 days. We sought to investigate the efficacy of this device in children with paroxysmal palpitations. METHODS: In phase I, the quality of tracings from simultaneous CardioSTAT recordings and D1-lead recordings of a standard 12-lead electrocardiography machine in 23 children were compared. Phase II was a prospective observational cohort study comparing arrhythmia detection using the CardioSTAT vs currently used devices (24-hour Holter monitor and the Cardiomemo loop recorder) in 52 children complaining of palpitations. RESULTS: In Phase I, all but 3 rhythm strips were correctly identified. The pacing spikes on 3 strips were not adequately identified by the observers for the CardioSTAT recording. In Phase II, symptomatic episodes were reported in 42%, 73%, and 100% of subjects during monitoring with the Holter, Cardiomemo, and CardioSTATdevices, respectively. An abnormal rhythm was detected in 13%, 23%, and 35% of subjects by the Holter, Cardiomemo, and CardioSTAT monitors, respectively. The underlying rhythm during symptomatic events was determined in 90% of cases with the CardioSTAT monitor, whereas it was determined in only 19% and 29% of cases using the Holter and Cardiomemo monitors, respectively. CONCLUSIONS: The CardioSTAT monitor provided good-quality tracings and was superior to the 24-hour Holter monitor and the Cardiomemo loop recorder in determining the presence or absence of pathologic arrhythmia in the study cohort.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".