MétaCan
Menu
Back to cohort
Record W3178223692 · doi:10.1080/15412555.2021.1945021

The Performance of Digital Monitoring Devices for Oxygen Saturation and Respiratory Rate in COPD: A Systematic Review

2021· review· en· W3178223692 on OpenAlexaff
Ava Mehdipour, Elise Wiley, Julie Richardson, Marla Beauchamp, Ayse Kuspinar

Bibliographic record

VenueCOPD Journal of Chronic Obstructive Pulmonary Disease · 2021
Typereview
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsMcMaster University
Fundersnot available
KeywordsCINAHLMedicineTelehealthCOPDMEDLINEConvergent validityValidityExacerbationReliability (semiconductor)Intensive care medicineTelemedicineHealth carePsychological interventionInternal medicinePsychometricsNursingClinical psychologyInternal consistency

Abstract

fetched live from OpenAlex

Healthcare access and delivery for individuals with chronic obstructive pulmonary disease (COPD) who live in remote areas or who are susceptible to contracting communicable diseases, such as COVID-19, may be a challenge. Telehealth and remote monitoring devices can be used to overcome this issue. However, the accuracy of these devices must be ensured before forming healthcare decisions based on their outcomes. Therefore, a systematic review was performed to synthesize the evidence on the reliability, validity and responsiveness of digital devices used for tracking oxygen saturation (SpO2) and/or respiratory rate (RR) in individuals with COPD, in remote settings. Three electronic databases were searched: MEDLINE (1996 to October 8, 2020), EMBASE (1996 to October 8, 2020) and CINAHL (1998 to October 8, 2020). Studies were included if they aimed to evaluate one or more measurement properties of a digital device measuring SpO2 or RR in individuals with COPD. Six-hundred and twenty-five articles were identified and after screening, 7 studies matched the inclusion criteria; covering 11 devices measuring SpO2 and/or RR. Studies reported on the reliability (n = 1), convergent validity (n = 1), concurrent validity (n = 2) and predictive validity (n = 2) of SpO2 devices and on the convergent validity (n = 1), concurrent validity (n = 1) and predictive validity (n = 1) of RR devices. SpO2 and RR devices were valid when compared against other respiration monitoring devices but were not precise in predicting exacerbation events. More well-designed measurement studies are needed to make firm conclusions about the accuracy of such devices.Supplemental data for this article is available online at https://doi.org/10.1080/15412555.2021.1945021 .

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.148
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.001
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.336
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueCOPD Journal of Chronic Obstructive Pulmonary DiseaseSame topicChronic Obstructive Pulmonary Disease (COPD) ResearchFrench-language works237,207