MétaCan
Menu
Back to cohort
Record W3180552494 · doi:10.1002/mrm.28915

An asymmetrical whole‐body birdcage RF coil without RF shield for hyperpolarized <sup>129</sup>Xe lung MR imaging at 1.5 T

2021· article· en· W3180552494 on OpenAlexaff
Claudio Puddu, Madhwesha Rao, Xiaojun Xu, Martin H. Deppe, Guilhem Collier, Adam Maunder, Ho‐Fung Chan, Nicola De Zanche, Fraser Robb, Jim M. Wild

Bibliographic record

VenueMagnetic Resonance in Medicine · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsUniversity of Alberta
FundersMedical Research Council
KeywordsRadiofrequency coilElectromagnetic coilRadio frequencyXenonNuclear magnetic resonanceScannerRF probePhysicsRF power amplifierMaterials scienceOpticsAtomic physicsOptoelectronics

Abstract

fetched live from OpenAlex

Purpose This study describes the development and testing of an asymmetrical xenon‐129 ( 129 Xe) birdcage radiofrequency (RF) coil for 129 Xe lung ventilation imaging at 1.5 Tesla, which allows proton ( 1 H) system body coil transmit–receive functionality. Methods The 129 Xe RF coil is a whole‐body asymmetrical elliptical birdcage constructed without an outer RF shield to enable 1 H imaging. field homogeneity and flip angle mapping of the 129 Xe birdcage RF coil and 1 H system body RF coil with the 129 Xe RF coil in situ were evaluated in the MR scanner. The functionality of the 129 Xe birdcage RF coil was demonstrated through hyperpolarized 129 Xe lung ventilation imaging with the birdcage in both transceiver configuration and transmit‐only configuration when combined with an 8‐channel 129 Xe receive‐only RF coil array. The functionality of 1 H system body coil with the 129 Xe RF coil in situ was demonstrated by acquiring coregistered 1 H lung anatomical MR images. Results The asymmetrical birdcage produced a homogeneous field (±10%) in agreement with electromagnetic simulations. Simulations indicated an optimal detuning configuration with 4 diodes. The obtained g‐factor of 1.4 for acceleration factor of R = 2 indicates optimal array configuration. Coregistered 1 H anatomical images from the system body coil along with 129 Xe lung images demonstrated concurrent and compatible arrangement of the RF coils. Conclusion A large asymmetrical birdcage for homogenous transmission with high sensitivity reception for 129 Xe lung MRI at 1.5 Tesla has been demonstrated. The unshielded asymmetrical birdcage design enables 1 H structural lung MR imaging in the same exam.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.841
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.310
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207