Blood pressure measurement: Should technique define targets?
Bibliographic record
Abstract
Accurate assessment of blood pressure (BP) is the cornerstone of hypertension management. The objectives of this study were to quantify the effect of medical personnel presence during BP measurement by automated oscillometric BP (AOBP) and to compare resting office BP by AOBP to daytime average BP by 24-h ambulatory BP monitoring (ABPM). This study is a prospective randomized cross-over trial, conducted in a referral population. Patients underwent measurements of casual and resting office BP by AOBP. Resting BP was measured as either unattended (patient alone in the room during resting and measurements) or as partially attended (nurse present in the room during measurements) immediately prior to and after 24-h ABPM. The primary outcome was the effect of unattended 5-min rest preceding AOBP assessment as the difference between casual and resting BP measured by the Omron HEM 907XL. Ninety patients consented and 78 completed the study. The mean difference between the casual and Omron unattended systolic BP was 7.0 mm Hg (95% confidence interval [CI] 4.5, 9.5). There was no significant difference between partially attended and unattended resting office systolic BP. Resting office BP (attended and partially attended) underestimated daytime systolic BP load from 24-h ABPM. The presence or absence of medical personnel does not impact casual office BP which is higher than resting office AOBP. The requirement for unattended rest may be dropped if logistically challenging. Casual and resting office BP readings by AOBP do not capture the complexity of information provided by the 24-h ABPM.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.005 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".