MétaCan
Menu
← Back to cohort
Record W3181389512 · doi:10.1371/journal.pone.0254399

The effect of acute ventilation-perfusion mismatch on respiratory heat exchange in a porcine model

2021· article· en· W3181389512 on OpenAlexaboutno aff
Maximilian Edlinger-Stanger, Martin H. Bernardi, Katharina Kovacs, Michael Mascha, Thomas Neugebauer, S. Böhme, Nathan Ayoubi, Nico Christofi, James Garry, Neal Fleming, M. Hiesmayr

Bibliographic record

VenuePLoS ONE · 2021
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsnot available
FundersMedizinische Universität WienUniversität Wien
KeywordsMedicineVentilation (architecture)LungVentilation perfusion mismatchAnesthesiaRespiratory systemPulmonary arteryPerfusionCardiologyInternal medicineLung volumes

Abstract

fetched live from OpenAlex

BACKGROUND: Respiratory heat exchange is an important physiological process occurring in the upper and lower respiratory tract and is usually completed when inspired gases reach the alveoli. Animal and human studies demonstrated that heat exchange can be modulated by altering pulmonary ventilation and perfusion. The purpose of this study was to examine the effect of acute ventilation-perfusion (V/Q) mismatch on respiratory heat exchange. In clinical practice, monitoring respiratory heat exchange might offer the possibility of real-time tracking of acute V/Q-mismatch. METHODS: In 11 anesthetized, mechanically ventilated pigs, V/Q-mismatch was established by means of four interventions: single lung ventilation, high cardiac output, occlusion of the left pulmonary artery and repeated whole-lung lavage. V/Q-distributions were determined by the multiple inert gas elimination technique (MIGET). Respiratory heat exchange was measured as respiratory enthalpy using the novel, pre-commercial VQm™ monitor (development stage, Rostrum Medical Innovations, Vancouver, CA). According to MIGET, shunt perfusion of low V/Q compartments increased during single lung ventilation, high cardiac output and whole-lung lavage, whereas dead space and ventilation of high V/Q compartments increased during occlusion of the left pulmonary artery and whole-lung lavage. RESULTS: Bohr dead space increased after pulmonary artery occlusion and whole-lung lavage, venous admixture increased during single lung ventilation and whole-lung lavage, PaO2/FiO2 was decreased during all interventions. MIGET confirmed acute V/Q-mismatch. Respiratory enthalpy did not change significantly despite significant acute V/Q-mismatch. CONCLUSION: Clinically relevant V/Q-mismatch does not impair respiratory heat exchange in the absence of additional thermal stressors and may not have clinical utility in the detection of acute changes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.275
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONE→Same topicRespiratory Support and Mechanisms→French-language works237,207→