Study of a Modified Obstruction Free Pressure Sensor Based Flow Transducer Using Hall Sensors
Bibliographic record
Abstract
In the present paper, a modified obstruction free pressure sensor-based flow transducer has been developed using Hall sensors. This technique is a modified version of the earlier inductive method. In this transducer, the fluid pressure in the pipeline is taken as the flow sensing parameter, and various drawbacks of the earlier inductive technique are eliminated. A prototype unit of the transducer is developed and studied in the present work. The transducer consists of two identical C-type Bourdon gauges, each fitted with an identical permanent magnet and Hall sensor assembly to sense the fluid pressure under flow condition and static pressure under no flow condition. The difference between the two Hall sensor outputs is found to vary nonlinearly with flow rate. The mathematical relations describing the working of the prototype unit are derived in the paper. The static characteristic curves of the proposed flow transducer are determined experimentally and reported in the paper. The characteristic curves are found to follow the derived equations to a very good extent with negligible percentage deviation from best-fit nonlinear characteristic.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".