MétaCan
Menu
Back to cohort
Record W3189370443 · doi:10.1503/cjs.012420

Intraoperative measurement of acetabular component position using imageless navigation during revision total hip arthroplasty

2021· article· en· W3189370443 on OpenAlexaffvenue
Xin Y. Mei, Ali Etemad-Rezaie, Oleg Safir, Allan E. Gross, Paul R.T. Kuzyk

Bibliographic record

VenueCanadian Journal of Surgery · 2021
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsMount Sinai Hospital
Fundersnot available
KeywordsMedicineTotal hip arthroplastyAcetabulumPosition (finance)ArthroplastyComponent (thermodynamics)OrthodonticsSurgeryRadiology

Abstract

fetched live from OpenAlex

Background: Acetabular component malposition is a major cause of dislocation following total hip arthroplasty (THA). Intellijoint HIP is an imageless navigation tool that has been shown to provide accurate intraoperative measurement of cup position during primary THA without substantially increasing operative time. However, its accuracy in revision THA has not been evaluated. This study therefore aims to assess the accuracy of Intellijoint HIP in measuring cup inclination and anteversion in comparison with computed tomography (CT) during revision THA. Methods: Intellijoint HIP was used to measure the position of the preexisting cup in 53 consecutive patients undergoing revision THA between December 2018 and February 2020. Two authors blinded to the intraoperative navigation measurements also independently measured cup position using preoperative CT according to Murray’s radiographic definitions. Pearson correlation coefficients with 95% confidence intervals (CIs), paired t tests and Bland–Altman plots were used to assess agreement between navigation- and CT-measured cup position. Statistical analysis was performed using GraphPad Prism, with p values less than 0.05 indicating statistical significance. Results: There was excellent agreement between navigation and CT measurements for both cup inclination (r = 0.89, 95% CI 0.81–0.93) and anteversion (r = 0.93, 95% CI 0.88–0.96), with the mean absolute difference being 5.2º (standard deviation [SD] 4.0º) for inclination and 4.8º (SD 5.4º) for anteversion. The navigation measurement was within 10º of the radiographic measurement in 47 of 53 (88.7%) cases for inclination and 46 of 53 (86.8%) cases for anteversion. Conclusion: Imageless navigation demonstrated excellent correlation and agreement with CT measurements for both inclination and anteversion over a wide range of acetabular component positions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.250
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207