MétaCan
Menu
Back to cohort

Mapping Analysis of Active Fire Protection System on Dormitory Building in X University

2021· article· en· W3190966885 on OpenAlexfundno aff
Eka Rosanti, Selamet Ujang Irawan, Rindang Diannita, Muhammad Rifki Taufik

Bibliographic record

VenueThe Indonesian Journal of Occupational Safety and Health · 2021
Typearticle
Languageen
FieldHealth Professions
TopicOccupational Health and Safety Management
Canadian institutionsnot available
FundersRyerson University
KeywordsChecklistFlammable liquidFire protectionFire safetyArchitectural engineeringUnit (ring theory)ALARMActive fire protectionFire preventionComputer scienceEngineeringCivil engineeringPsychologyWaste managementElectrical engineeringMathematics education

Abstract

fetched live from OpenAlex

Introduction: Fire cases increase in residential buildings because short circuits, at dormitories are mostly affected by human factors. X university dormitory building is a place for 24 hours of students’ activities with a lot of electricity consumption, bad behavior; overpowering extensions, and many flammable objects such as paper and furniture. Research objectives are to investigate the appropriateness and mapping needs of fire protection systems with regulations. Methods: The research is a semi quantitative analysis. Primary data is conducted with observations by using a checklist form that refers to the regulations and results of managers' interviews. The obtained data are categorized into good with suitability >79-100%, moderate ≥60%-79% and poor <60%. Result: The appropriateness of the active fire protection system is under 60% or in the poor category. The appropriateness of the fire extinguisher is 47.77%, the hydrant is 58.75%, the alarm is 18.75% and the heat detector is 35.90%. There is no sprinkler installation in the dormitory building and no commitment from the top management regarding occupational safety and health. Fire extinguisher’s need is 10 tubes per floor, the number of hydrants have been fulfilled, alarm requires an additional 1 unit on each floor and a heat detector requires a total of 114 units. Conclusion: The active fire protection system is still under 60% (poor category) and no maintenances. Based on the aforementioned mapping results, it needs to add the number of piece equipment according to the regulations and maintenance efforts.Keywords: active fire protection system, dormitory, mapping

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.089
GPT teacher head0.389
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueThe Indonesian Journal of Occupational Safety and HealthSame topicOccupational Health and Safety ManagementFrench-language works237,207