MétaCan
Menu
Back to cohort
Record W3196769035 · doi:10.1097/icb.0000000000001187

IMMEDIATE SUBRETINAL FLUID DISPLACEMENT FROM THE BUOYANT FORCE OF A SMALL GAS BUBBLE IN PNEUMATIC RETINOPEXY: INSIGHTS INTO THE POTENTIAL MECHANISM OF RETINAL DISPLACEMENT AFTER RETINAL DETACHMENT REPAIR

2021· article· en· W3196769035 on OpenAlex
Wei Wei Lee, Arun Ramachandran, Hesham Hamli, Luis C. Escaf, Aditya Bansal, Rajeev H. Muni

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueRetinal Cases & Brief Reports · 2021
Typearticle
Languageen
FieldMedicine
TopicRetinal and Macular Surgery
Canadian institutionsKensington HealthUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsVitrectomyPars planaRetinal detachmentDisplacement (psychology)RetinalGas bubbleMedicineRetinaBubbleOphthalmologyFundus (uterus)MechanicsPhysicsOpticsVisual acuity

Abstract

fetched live from OpenAlex

PURPOSE: To demonstrate how a small gas bubble injected into the vitreous cavity in pneumatic retinopexy for rhegmatogenous retinal detachment causes immediate displacement of subretinal fluid and to gain insights into the potential mechanism of retinal displacement. METHODS: Three patients with rhegmatogenous retinal detachment who underwent pneumatic retinopexy were enrolled and prospectively followed. All patients underwent ultra-widefield fundus photography at baseline and at 1 to 2 minutes after intravitreal gas injection. RESULTS: In all cases, the ultra-widefield fundus photograph demonstrated immediate displacement of subretinal fluid, suggesting that the buoyant force applied to the retina by the bubble was responsible for the displacement of subretinal fluid. The results were extrapolated to determine the buoyant force applied by a small and large gas bubble as in pneumatic retinopexy and pars plana vitrectomy. We determined that the buoyant force applied with a larger bubble in pars plana vitrectomy was substantially greater, and this may lead to retinal displacement. CONCLUSION: Intravitreal gas applies significant buoyant force to the detached retina and subretinal fluid that leads to substantial and rapid displacement of subretinal fluid. Understanding the affect of the buoyant force of the gas bubble on the detached retina can provide insight into possible mechanisms of retinal displacement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.187
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.238
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it