MétaCan
Menu
Back to cohort
Record W3199126643 · doi:10.1016/j.ijporl.2021.110930

WRISTOX2 is a reliable tool to diagnose obstructive sleep apnoea syndrome

2021· article· en· W3199126643 on OpenAlexaboutno aff
Surendran Thavagnanam, Shih Ying Hng, Anna Marie Nathan, Kah Peng Eg, Karuthan Chinna, Siti Hajar Bte Turbirin, Jessie Anne de Bruyne

Bibliographic record

VenueInternational Journal of Pediatric Otorhinolaryngology · 2021
Typearticle
Languageen
FieldMedicine
TopicObstructive Sleep Apnea Research
Canadian institutionsnot available
FundersUniversiti Malaya
KeywordsMedicinePulse oximetryPolysomnographyPredictive valuePredictive value of testsObstructive sleep apneaDiagnostic accuracyInternal medicineAnesthesiaApnea

Abstract

fetched live from OpenAlex

Introduction Overnight pulse oximetry is an alternative to polysomnography (PSG) in diagnosing obstructive sleep apnoea syndrome , but its sensitivity is reported to be low. Aims To determine the (a) diagnostic accuracy, interobserver reliability and reliable oxygen desaturation index of 4% (ODI 4 ) score at diagnosing obstructive sleep apnoea syndrome in children and (b) correlation between the apnoea hypopnoea index (AHI) with ODI 4 and oxygen nadir between both PSG and oximetry . Methods This cross-sectional study included children aged 1–18 years old, undergoing a fully attended overnight PSG for suspected obstructive sleep apnoea syndrome. The Nonin 3150 WristOx 2 ™ [Fig. 2] was worn simultaneously during the PSG. Poor oximetry recordings were excluded. Pulse oximetry was scored using the McGill Oximetry Score (MOS) whereby a score of 2–4 was positive for OSAS. Specificity, sensitivity, positive predictive values (PPV), negative predictive values (NPV) and interobserver reliability of the WristOx 2 were calculated. Results One hundred and sixty-two children with a mean (SD) age of 9.3 (±3.5) years (range 2 years 6 months old - 17 years old) were included after excluding 18 children (poor oximetry data [n = 16] and incomplete PSG [n = 2]). Interobserver agreement of the WristOx 2 was 0.8763 (95% CI:0.80, 0.95). WristOx 2 had a sensitivity 50%, specificity 96.7%, PPV 96% and NPV 53% at diagnosing OSAS. ODI 4 ≥ 2 events/hour in oximetry had a sensitivity of 97.6% and negative predictive value of 85.7% at diagnosing OSA. Conclusion Overnight pulse oximetry with the Nonin 3150 WristOx 2 ™ is an accurate and reliable tool in diagnosing significant OSAS in children.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.303
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Pediatric OtorhinolaryngologySame topicObstructive Sleep Apnea ResearchFrench-language works237,207