Recent Progress in the Development of a-Se/CMOS Sensors for X-ray Detection
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Amorphous selenium (a-Se) is a glass-former capable of deposition at high rates by thermal evaporation over a large area. It was chosen as a direct conversion material due to its appealing properties for imaging in both low and high X-ray energy ranges (<30 keV and <30 keV, respectively). It has a bandgap of 2.2 eV and can achieve high photodetection efficiency at short wavelengths less than 400 nm which makes it appealing for indirect conversion detectors. The integration of a-Se with readout integrated circuits started with thin-film transistors for digital flat panel X-ray detectors. With increasing applications in life science, biomedical imaging, X-ray imaging, high energy physics, and industrial imaging that require high spatial resolution, the integration of a-Se and CMOS is one direct way to improve the high-contrast visualization and high-frequency response. Over the past decade, significant improvements in a-Se/CMOS technologies have been achieved with improvements to modulation transfer function and detective quantum efficiency. We summarize recent advances in integrating and photon-counting detectors based on a-Se coupled with CMOS readout and discuss some of the shortcomings in the detector structure, such as low charge conversion efficiency at low electric field and high dark current at high electric field. Different pixel architectures and their performance will be highlighted.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it