CALIBRATION METHOD AND ABSOLUTE MEASUREMENTS OF AIR KERMA OF DIAGNOSTIC X-RAY REFERENCE QUALITIES USING A FREE-AIR IONISATION CHAMBER
Bibliographic record
Abstract
Accurate dose measurement is very important for diagnosing X-ray equipment. These equipment should be traced directly or indirectly to primary standard with as little uncertainty as possible. A parallel-plate free-air chamber was designed to measure air kerma of diagnostic X-ray absolutely. Different thickness of aluminium filters were used to obtain different radiation qualities according with IEC 61267. Correction factors were obtained by experiments and simulation, especially the air attenuation factor measured with vacuum method. The relative standard uncertainty of air kerma rate measurement was 0.46% and calibration factor was 0.53%. A transfer ionisation chamber was calibrated with Radiation Qualities in Radiation beams (RQR) qualities in National Research Council of Canada and National Institute of Metrology (NIM), the differences of calibration factors are less than 0.68%.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".