MétaCan
Menu
Back to cohort
Record W3213223842 · doi:10.3390/su132112250

Studying Energy Performance and Thermal Comfort Conditions in Heritage Buildings: A Case Study of Murabba Palace

2021· article· en· W3213223842 on OpenAlex
Abobakr Al-Sakkaf, Eslam Mohammed Abdelkader, Sherif Mahmoud, Ashutosh Bagchi

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueSustainability · 2021
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsConcordia University
Fundersnot available
KeywordsRetrofittingThermal insulationMaterials scienceThermalExpanded polystyreneThermal comfortComposite materialVacuum insulated panelStructural engineeringEngineeringLayer (electronics)Meteorology

Abstract

fetched live from OpenAlex

Heritage buildings are significant historical and architecture added value, which requires deep and precise preliminary brainstorming when considering upgrading or retrofitting these valuable buildings. In this study, we opted to highlight some passive design architecture interventions to improve the thermal comfort and the required cooling energy for buildings. The Murabba Palace in Riyadh was selected as a case study. DesignBuilder software was used to evaluate the energy performance of ten passive architectural design alternatives throughout different seasons in an attempt to improve the energy performance and thermal comfort of heritage buildings. The ten passive design scenarios encompassed double low-E glass, double reflected glass, double low-E glass and double wall with an air gap, double low-E glass and double wall with thermal insulation, double low-E glass and double wall with lightweight thermal insulation, double low-E glass and double wall with sprayed foam insulation, double reflected glass and double wall with an air gap, double reflected glass and double wall with thermal insulation, double reflected glass and double wall with lightweight thermal insulation, and double reflected glass and double wall with sprayed foam insulation. The results show that using double low-E glass and applying a double wall with polystyrene thermal insulation can enhance the thermal comfort inside the building and reduce the energy performance and CO2 emissions to 17% and 9%, respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.163
Threshold uncertainty score0.498

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.224
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it