MétaCan
Menu
Back to cohort
Record W3213658351 · doi:10.2340/jrm.v53.807

Effect of multi-grip myoelectric prosthetic hands on daily activities, pain-related disability and prosthesis use compared with single-grip myoelectric prostheses: A single-case study

2021· article· en· W3213658351 on OpenAlexaboutno aff
Cathrine Widehammar, Ayako Hiyoshi, Kajsa Lidström-Holmqvist, Helen Lindner, Liselotte Hermansson

Bibliographic record

VenueJournal of Rehabilitation Medicine · 2021
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsnot available
Fundersnot available
KeywordsGrip strengthPhysical medicine and rehabilitationMedicineProsthesisPhysical therapyHand strengthActivities of daily livingSurgery

Abstract

fetched live from OpenAlex

OBJECTIVE: To evaluate the effect of multi-grip myoelectric prosthetic hands on performance of daily activities, pain-related disability and prosthesis use, in comparison with single-grip myoelectric prosthetic hands. Design: Single-case AB design. PATIENTS: Nine adults with upper-limb loss participated in the study. All had previous experience of single-grip myoelectric prostheses and were prescribed a prosthesis with multi-grip functions. METHODS: To assess the changes in daily activities, pain-related disability and prosthesis use between single-grip and multi-grip myoelectric prosthetic hands, the Canadian Occupational Performance Measure, Pain Disability Index, and prosthesis wearing time were measured at multiple time-points. Visual assessment of graphs and multi-level linear regression were used to assess changes in the outcome measures. Results: At 6 months' follow-up self-perceived performance and satisfaction scores had increased, prosthesis wearing time had increased, and pain-related disability had reduced in participants with musculoskeletal pain at baseline. On average, 8 of the 11 available grip types were used. Most useful were the power grip, tripod pinch and lateral pinch. Conclusion: The multi-grip myoelectric prosthetic hand has favourable effects on performance of, and satisfaction with, individually chosen activities, prostheses use and pain-related disability. A durable single-grip myoelectric prosthetic hand may still be needed for heavier physical activities. With structured training, a standard 2-site electrode control system can be used to operate a multi-grip myoelectric prosthetic hand.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.244
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Rehabilitation MedicineSame topicMuscle activation and electromyography studiesFrench-language works237,207