MétaCan
Menu
← Back to cohort
Record W3214155149 · doi:10.23750/abm.v92is1.11737

Early complication of a subtrochanteric periprosthetic fracture following hip resurfacing. Is varus healing acceptable? A case report and literature review.

2021· article· en· W3214155149 on OpenAlexaff
Giovanni Lugani, Alessandro Santandrea, Leonardo Puddu, Massimo Rigoni, Fabrizio Cont, Bruno Magnan, Fabrizio Cortese

Bibliographic record

VenuePubMed · 2021
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsPurdue Pharma (Canada)
Fundersnot available
KeywordsPeriprostheticMedicineHip resurfacingSurgeryVarus deformityOsteosynthesisComplicationReduction (mathematics)Hip fractureOsteoarthritisProsthesisFemurArthroplastyOsteoporosis

Abstract

fetched live from OpenAlex

BACKGROUND: The increase in the incidence of osteoarthritis of the hip (coxarthrosis) in young patients with high functionality requirements and the development of new materials in the last twenty years have resulted in an increase in the number of surgeries involving hip resurfacing procedures. There has also been an increase in associated periprosthetic fractures, which currently occur in 1%-2% of cases. According to the medical literature, fractures of this type can be treated conservatively, using reduction and synthesis or through prosthetic revision. CASE REPORT: Patient aged 69 years who had undergone resurfacing of the right hip ten years previously, who came to our attention as a result of direct contusion trauma with x-ray evidence of a periprosthetic fracture in the subtrochanteric region. We treated the fracture by preserving the prosthesis and performing osteosynthesis using a plate and screws. After two months the synthesis was complicated by breakage of a proximal screw and varus collapse of the fracture. We treated this complication conservatively by adjusting the weight-bearing regime and administering physical and drug therapy. Six months after the fracture, despite the residual varus displacement and the less than stellar x-ray result, the clinical outcome was satisfactory. Discussion and conclusions: Treatment of periprosthetic fractures following hip resurfacing is often technically complex. The major difficulties arise from the presence of prosthetic components and the limited bone stock available. Fractures often affect the neck of the femur and the trochanteric region, and in rare cases there is involvement of the subtrochanteric region. Our review confirms this trend and raises the question as to which method of synthesis is ideal for a fracture pattern so rarely described in the literature.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0030.003
Science and technology studies0.0020.002
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0070.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.269
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venuePubMed→Same topicOrthopaedic implants and arthroplasty→French-language works237,207→