MétaCan
Menu
Back to cohort
Record W3214371519 · doi:10.1002/er.7454

Operating performance of multi‐modular water‐phase change material tanks for emergency cooling in an underground shelter

2021· article· en· W3214371519 on OpenAlexaff
Chao Zeng, Xiaoling Cao, Mohamed Dardir, Karthik Panchabikesan, Wenhui Ji, Ziyu Leng

Bibliographic record

VenueInternational Journal of Energy Research · 2021
Typearticle
Languageen
FieldEngineering
TopicPhase Change Materials Research
Canadian institutionsConcordia University
FundersChengdu Science and Technology ProgramInternational Energy AgencyNational Natural Science Foundation of China
KeywordsThermal energy storagePhase-change materialStorage tankModular designLatent heatThermal massThermalEngineeringFlexibility (engineering)Matrix (chemical analysis)Environmental scienceNuclear engineeringPetroleum engineeringPhase changeWaste managementMaterials scienceComputer scienceThermodynamicsComposite materialMathematics

Abstract

fetched live from OpenAlex

Latent heat thermal energy storage can not only alleviate the mismatch between supply and demand but also improve the performance and dependability of the energy system. Unfortunately, previous research achieves a specific engineering load shifting using a single water-phase change material (PCM) tank, the volume of which is tailored to the specific cooling or heating load. This paper proposes the concept of multi-modular water-PCM tanks (MMWPT), which offer flexibility and are simple to be mass-produced, as thermal storage in an underground shelter's emergency mode. The thermal inertia of the geothermal energy is used to remain the PCM at solid state at first and to naturally cool the tank once they are melted. The mathematical model is created in MATLAB and validated by experiment with an NMBE of less than ±10% and RMSE of less than 30%. In addition, the MMWPT's thermal performance in various matrixes was investigated in an underground shelter where the peak load occurs suddenly and with low frequency. The result reveals that the ∆Twater in the scenario with matrix form of N (number of tanks in series) × 5 (number of tanks in parallel) is almost four times as that with matrix form of N × 1. By separating the water into five parallel water tanks, the corresponding EDD is 1.27-1.28 times larger. Changing the N from 1 to 2 and 3 could increase the EDD by 3.0%-12.5% and 5.9%-25%, respectively. Three acceptable MMWPT matrixes were presented using the effective discharging duration (EDD) and temperature drop as assessment criteria. Additionally, PCM with a maximum phase change temperature () of 19.41°C and a connection matrix of 3 × 4 is recommended when using a single charging cycle or active cooling approach. Otherwise, a of 22.41°C with a connection matrix of 3 × 5 is advised. This research is planned to give references for using the MMWPT in underground shelters to shift loads.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.111
Threshold uncertainty score0.576

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.201
GPT teacher head0.441
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Energy ResearchSame topicPhase Change Materials ResearchFrench-language works237,207