MétaCan
Menu
Back to cohort
Record W3216922782 · doi:10.1136/gutjnl-2021-324729

Estimating the environmental impact of disposable endoscopic equipment and endoscopes

2021· article· en· W3216922782 on OpenAlexaff
Sathvik Namburar, Daniel von Renteln, John Damianos, Lisa Bradish, Jeanne Barrett, Andres Aguilera-Fish, Benoı̂t Cushman-Roisin, Heiko Pohl

Bibliographic record

VenueGut · 2021
Typearticle
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsCentre Hospitalier de l’Université de Montréal
Fundersnot available
KeywordsMedical wasteMedicineEndoscopeAuditWaste managementHospital wasteEndoscopyWaste disposalSurgeryEnvironmental scienceEngineeringBusiness

Abstract

fetched live from OpenAlex

OBJECTIVE: Procedure-intense specialties, such as surgery or endoscopy, are a major contributor to the impact of the healthcare sector on the environment. We aimed to measure the amount of waste generated during endoscopic procedures and to understand the impact on waste of changing from reusable to single use endoscopes in the USA. DESIGN: We conducted a 5-day audit (cross-sectional study) of all endoscopies performed at two US academic medical centres with low and a high endoscopy volume (2000 and 13 000 procedures annually, respectively). We calculated the average disposable waste (excluding waste from reprocessing) generated during one endoscopic procedure to estimate waste of all endoscopic procedures generated in the USA annually (18 million). We further estimated the impact of changing from reusable to single-use endoscopes taking reprocessing waste into account. RESULTS: 278 endoscopies were performed for 243 patients. Each endoscopy generated 2.1 kg of disposable waste (46 L volume). 64% of waste was going to the landfill, 28% represented biohazard waste and 9% was recycled. The estimated total waste generated during all endoscopic procedures performed in the USA annually would weigh 38 000 metric tons (equivalent of 25 000 passenger cars) and cover 117 soccer fields to 1 m depth. If all endoscopic procedures were performed with single-use endoscopes and accounting for reprocessing, the net waste mass would increase by 40%. Excluding waste from ancillary supplies, net waste generated from reprocessing and endoscope disposal would quadruple with only using single-use endoscopes. CONCLUSION: This quantitative assessment of the environmental impact of endoscopic procedures highlights that a large amount of waste is generated from disposable instruments. Transitioning to single-use endoscopes may reduce reprocessing waste but would increase net waste.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.736
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.263
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations154
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueGutSame topicMedical Device Sterilization and DisinfectionFrench-language works237,207