MétaCan
Menu
Back to cohort

Biomechanical Modelling of a Direct Vertebral Translation Instrumentation System: Preliminary Results

2008· article· en· W41137204 on OpenAlexaff
Xinhua Wang, Aubin C.- Eacute ., Hubert Labelle, Dennis G. Crandall

Bibliographic record

VenueStudies in health technology and informatics · 2008
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsPolytechnique Montréal
Fundersnot available
KeywordsVertebraCoronal planeBiomechanicsSagittal planeKinematicsInstrumentation (computer programming)Translation (biology)CadaverComputer scienceOrthodonticsMedicineAnatomyPhysics

Abstract

fetched live from OpenAlex

Many new spine instrumentation concepts were introduced in recent years, like the incremental direct vertebral translation. The objective was to develop a biomechanical model in order to analyze the biomechanics of this instrumentation system. The patient-specific spine model was built using the 3D reconstruction based on bi-planar radiographs of a scoliotic patient (thoraco-lumbar Cobb: 49 degrees ). The mechanical properties were derived from literature, experiments on cadaver spines and patient's side bending radiographs. Each screw construct was modelled by four rigid bodies connected each other by kinematic joints. The screw-vertebra flexible joint was represented by 3 experimentally derived non-linear springs, and the rods by non-linear flexible elements. The correction manoeuvres were simulated by lowering the rod, tightening the crimps (incremental segmental translation) and applying secondary correction manoeuvres (direct vertebra derotation, compression, distraction and construct tightening). The simulations showed that the system allows a good force distribution among implants. The long post pushing and pulling contributed, to a great extent, to a global correction in the coronal plane, while the crimp tightening had more important effect in the sagittal plane. The preliminary results illustrated the effectiveness of local correction by a direct vertebra translation technique. Our next step is to validate the model and compare the performance of this strategy with other spinal instrumentation systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.795
Threshold uncertainty score0.265

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.112
GPT teacher head0.366
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueStudies in health technology and informaticsSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207