Dynamic Simulation of a Standalone Photovoltaic Hybrid System of a Remote house in Nigeria

2021· article· en· W4200338792 on OpenAlexaff
Japhet Ozogbuda, M. Tariq Iqbal

Bibliographic record

Venue2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) · 2021
Typearticle
Languageen
FieldEnergy
TopicHybrid Renewable Energy Systems
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsPhotovoltaic systemMaximum power point trackingBattery (electricity)Electrical engineeringBackupAutomotive engineeringGrid-connected photovoltaic power systemStand-alone power systemComputer scienceState of chargeVoltageMains electricityInverterEngineeringRenewable energyPower (physics)Distributed generation

Abstract

fetched live from OpenAlex

In the remote part of Nigeria, most households suffer from lack of electricity due to inaccessibility to the utility grid. This paper presents the simulation of a Photovoltaic (PV) hybrid system with battery and generator backup of an off-grid Stand-alone PV system for a house located in remote Benin City, Edo State in Nigeria. House peak load is 1.26kW and daily energy consumption is 3.4kWh, with no access to the electricity grid for fulfilment of load requirement to meet the basic electrical needs. The system is designed in Homer Pro and simulated using the Matlab Simulink software, it comprises of a 1.23kW PV made up of 4 modules (325W each with 2 in series and 2 in parallel), A MPPT (maximum power point tracking), a DC -DC buck converter, 4 backup battery of 12V, 350Ahr connected in series and a 4.8kW emergency generator system with a 1.6kW inverter which converts the output DC voltage of 48V from the converter to an alternating AC. The inverter is connected directly to a step-up transformer which boosts the voltage from to 220V AC for supply to the load. Result shows different scenarios and configuration. With a 50% State of Charge (SOC) of the battery and full electrical load, the PV charges the battery and supply power to the load. However, when the volatage of the battery is below 49V the emergency generator turns ON to charge up the battery. Whereas, in the scenario of 98% SOC of the battery, regardless of the load, the generator is not operational because the control of the generator automatically turns off when the battery is above 49V. The system dynamic simulation results and response to changing inputs are presented in this paper.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.020
Threshold uncertainty score0.040

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.240
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same venue2021 IEEE 12th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON)Same topicHybrid Renewable Energy SystemsFrench-language works237,207