MétaCan
Menu
Back to cohort
Record W4205903485 · doi:10.21203/rs.3.rs-1228467/v1

Optimization of Spatial Resolution and Image Reconstruction Parameters for the Small-Animal MetisTM PET/CT System

2022· preprint· en· W4205903485 on OpenAlexaboutno aff
Jie Zhao, Qiong Liu, Chaofan Li, Yunfeng Song, Ying Zhang, Mejia Jose, Jyh‐Cheng Chen

Bibliographic record

VenueResearch Square · 2022
Typepreprint
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsnot available
FundersXuzhou Medical UniversityGovernment of Jiangsu ProvinceChina Postdoctoral Science Foundation
KeywordsImaging phantomImage resolutionImage qualityIterative reconstructionFull width at half maximumGaussian filterVoxelGaussianContrast-to-noise ratioFilter (signal processing)Noise (video)Artificial intelligenceComputer scienceImage noiseContrast (vision)Reconstruction filterComputer visionOpticsNuclear medicinePhysicsImage (mathematics)Filter designMedicine

Abstract

fetched live from OpenAlex

Abstract The aim of this study was to investigate the optimization of spatial resolution and image reconstruction parameters related to image quality in an iterative reconstruction algorithm for the small-animal MetisTM PET/CT system. We used a homemade Derenzo phantom to evaluate the image quality by visual assessment, signal-to-noise ratio, contrast, coefficient of variation, and contrast-to-noise ratio of the 0.8 mm hot rods of 8 slices in the centre of the phantom PET images. A healthy mouse study was performed to analyze the influence of optimal reconstruction parameters and Gaussian post-filter FWHM. In the phantom study, the best image quality was obtained by placing the phantom at one end, keeping the central axis parallel to X-axis of the system, selecting iterations between 30 and 40, with a reconstruction voxel of 0.314 mm and a Gaussian post-filter FWHM of 1.57 mm. The optimization of spatial resolution can reach 0.6-mm. In the animal study, it was suitable to choose a voxel size of 0.472-mm, iterations between 30 and 40, and 2.36-mm Gaussian post-filter FWHM. Our results indicate that optimal imaging conditions and reconstruction parameters are necessary to obtain high-resolution images and quantitative accuracy, especially for the high-precision identification of tiny lesions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.087
GPT teacher head0.404
Teacher spread0.318 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueResearch SquareSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207