MétaCan
Menu
Back to cohort
Record W4205954025 · doi:10.1200/jco.21.01460

Blood-Based Biomarker Panel for Personalized Lung Cancer Risk Assessment

2022· article· en· W4205954025 on OpenAlexaff
Johannes F. Fahrmann, Tracey L. Marsh, Ehsan Irajizad, Nikul Patel, Eunice Murage, Jody V. Vykoukal, Jennifer B. Dennison, Kim‐Anh Do, Edwin J. Ostrin, Margaret R. Spitz, Stephen Lam, Sanjay Shete, Rafael Meza, Martin C. Tammemägi, Ziding Feng, Samir Hanash

Bibliographic record

VenueJournal of Clinical Oncology · 2022
Typearticle
Languageen
FieldMedicine
TopicLung Cancer Diagnosis and Treatment
Canadian institutionsCancer Care OntarioBrock University
FundersNational Cancer Institute
KeywordsMedicineInternal medicineReceiver operating characteristicLung cancerCancer screeningBiomarkerCarcinoembryonic antigenOncologyCancerColorectal cancer

Abstract

fetched live from OpenAlex

PURPOSE To investigate whether a panel of circulating protein biomarkers would improve risk assessment for lung cancer screening in combination with a risk model on the basis of participant characteristics. METHODS A blinded validation study was performed using prostate lung colorectal ovarian (PLCO) Cancer Screening Trial data and biospecimens to evaluate the performance of a four-marker protein panel (4MP) consisting of the precursor form of surfactant protein B, cancer antigen 125, carcinoembryonic antigen, and cytokeratin-19 fragment in combination with a lung cancer risk prediction model (PLCO m2012 ) compared with current US Preventive Services Task Force (USPSTF) screening criteria. The 4MP was assayed in 1,299 sera collected preceding lung cancer diagnosis and 8,709 noncase sera. RESULTS The 4MP alone yielded an area under the receiver operating characteristic curve of 0.79 (95% CI, 0.77 to 0.82) for case sera collected within 1-year preceding diagnosis and 0.74 (95% CI, 0.72 to 0.76) among the entire specimen set. The combined 4MP + PLCO m2012 model yielded an area under the receiver operating characteristic curve of 0.85 (95% CI, 0.82 to 0.88) for case sera collected within 1 year preceding diagnosis. The benefit of the 4MP in the combined model resulted from improvement in sensitivity at high specificity. Compared with the USPSTF2021 criteria, the combined 4MP + PLCO m2012 model exhibited statistically significant improvements in sensitivity and specificity. Among PLCO participants with ≥ 10 smoking pack-years, the 4MP + PLCO m2012 model would have identified for annual screening 9.2% more lung cancer cases and would have reduced referral by 13.7% among noncases compared with USPSTF2021 criteria. CONCLUSION A blood-based biomarker panel in combination with PLCO m2012 significantly improves lung cancer risk assessment for lung cancer screening.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.053

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.017
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.166
GPT teacher head0.533
Teacher spread0.366 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations99
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical OncologySame topicLung Cancer Diagnosis and TreatmentFrench-language works237,207