MétaCan
Menu
Back to cohort
Record W4207051190 · doi:10.1101/2021.08.16.456514

DARQ: Deep learning of quality control for stereotaxic registration of human brain MRI

2021· preprint· en· W4207051190 on OpenAlexafffund
Vladimir Fonov, Mahsa Dadar

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2021
Typepreprint
Languageen
FieldComputer Science
TopicMedical Image Segmentation Techniques
Canadian institutionsMcGill UniversityMontreal Neurological Institute and Hospital
FundersNIH Blueprint for Neuroscience ResearchPfizer CanadaNational Institutes of HealthGovernment of CanadaMcDonnell Center for Systems NeuroscienceMcGill UniversityConsortium canadien en neurodégénérescence associée au vieillissementPfizer
KeywordsArtificial intelligenceComputer scienceImage registrationNeuroimagingDeep learningTask (project management)Pattern recognition (psychology)Image qualityArtificial neural networkImage processingComputer visionImage (mathematics)Medicine

Abstract

fetched live from OpenAlex

Abstract Linear registration to stereotaxic space is a common first step in many automated image-processing tools for analysis of human brain MRI scans. This step is crucial for the success of the subsequent image-processing steps. Several well-established algorithms are commonly used in the field of neuroimaging for this task, but none have a 100% success rate. Manual assessment of the registration is commonly used as part of quality control. To reduce the burden of this time-consuming step, we propose Deep Automated Registration Qc (DARQ), a fully automatic quality control method based on deep learning that can replace the human rater and accurately perform quality control assessment for stereotaxic registration of T1w brain scans. In a recently published study from our group comparing linear registration methods, we used a database of 9325 MRI scans and 64476 registrations from several publicly available datasets and applied seven linear registration tools to them. In this study, the resulting images that were assessed and labeled by a human rater are used to train a deep neural network to detect cases when registration failed. We further validated the results on an independent dataset of patients with multiple sclerosis, with manual QC labels available (n=1200). In terms of agreement with a manual rater, our automated QC method was able to achieve 89%accuracy and 85% true negative rate (equivalently 15% false positive rate) in detecting scans that should pass quality control in a balanced cross-validation experiments, and 96.1% accuracy and 95.5% true negative rate (or 4.5% FPR) when evaluated in a balanced independent sample, similar to manual QC rater (test-retest accuracy of 93%). The results show that DARQ is robust, fast, accurate, and generalizable in detecting failure in linear stereotaxic registrations and can substantially reduce QC time (by a factor of 20 or more) when processing large datasets.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.016
metaresearch head score (Gemma)0.031
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.016
Threshold uncertainty score0.083

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0160.031
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.001
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0040.003
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.294
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes2
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)Same topicMedical Image Segmentation TechniquesFrench-language works237,207