Record W4210420583 · doi:10.1097/ftd.0000000000000969

Development and Validation of a Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) Assay for the Determination of Total and Unbound Ciprofloxacin Concentrations in Human Plasma

2022· article· en· W4210420583 on OpenAlexaff

Bibliographic record

VenueTherapeutic Drug Monitoring · 2022
Typearticle
Languageen
FieldMedicine
TopicAntibiotics Pharmacokinetics and Efficacy
Canadian institutionsInstitute of Infection and Immunity
FundersVifor PharmaNordic Pharma GroupBaxaltaCSL Behring
KeywordsHuman plasmaCiprofloxacinMass spectrometryPharmacokineticsPlasma concentrationLiquid chromatography–mass spectrometry

Abstract

fetched live from OpenAlex

BACKGROUND: Although unbound ciprofloxacin is responsible for antibacterial effects, assays measuring the unbound drug plasma concentrations are scarce. This study aimed to develop and validate a rapid, reproducible, and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of total and unbound ciprofloxacin plasma concentrations. METHODS: The determination of total ciprofloxacin concentrations required a 10 μL sample, while for unbound ciprofloxacin concentrations, it was 100 μL. Unbound ciprofloxacin was separated from protein-bound ciprofloxacin through ultrafiltration. A deuterated internal standard was used, and the sample preparation involved protein precipitation. The method was fully validated over a concentration range of 0.02-5.0 mg/L, according to the US Food and Drug Administration guidelines. In addition, its clinical application was demonstrated. RESULTS: The total run time was 1.5 minutes. For total ciprofloxacin plasma concentrations, the mean accuracy ranged from 94.5% to 105.0% across the validated range, the intraday imprecision was ≤7.6%, and the interday imprecision was ≤9.8%. For unbound ciprofloxacin plasma concentrations, the mean accuracy ranged from 92.8% to 102.1% across the validated range, the intraday imprecision was ≤7.0%, and the interday imprecision was ≤9.6%. Ciprofloxacin in plasma and ultrafiltrate remained stable for at least 96 hours at room temperature, at least 4 years at -80°C, and at least 3 freeze/thaw cycles (-80°C), with a minimum interval of 24 hours. CONCLUSIONS: The presented method is precise and accurate. It has been implemented in clinical care and research projects at a university hospital, permitting rapid determination of total and unbound ciprofloxacin.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.312
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueTherapeutic Drug MonitoringSame topicAntibiotics Pharmacokinetics and EfficacyFrench-language works237,207