MétaCan
Menu
Back to cohort

Prospective study on embolization of intracranial aneurysms with the pipeline device (PREMIER study): 3-year results with the application of a flow diverter specific occlusion classification

2022· article· en· W4221009727 on OpenAlexaff
Ricardó A. Hanel, Gustavo M Cortez, Demetrius K. Lopes, Peter K. Nelson, Adnan H. Siddiqui, Pascal Jabbour, Vítor Mendes Pereira, István Szikora, Osama O. Zaidat, Chetan Bettegowda, Geoffrey P. Colby, Maxim Mokin, Clemens M. Schirmer, Frank R Hellinger, Curtis A. Given, Timo Krings, Philipp Taussky, Gábor Tóth, Justin F. Fraser, Michael Chen, Ryan Priest, Peter Kan, David Fiorella, Donald Frei, Beverly Aagaard‐Kienitz, Orlando Díaz, Adel M. Malek, C. Michael Cawley, Ajit S Puri, David F. Kallmes

Bibliographic record

VenueJournal of NeuroInterventional Surgery · 2022
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsToronto Western Hospital
FundersGenentechCardinal HealthClaret MedicalStrykerBoston Scientific CorporationMedtronic
KeywordsMedicineOcclusionAneurysmEmbolizationRadiologyFlow diverterSurgeryProspective cohort study

Abstract

fetched live from OpenAlex

BACKGROUND: The pipeline embolization device (PED; Medtronic) has presented as a safe and efficacious treatment for small- and medium-sized intracranial aneurysms. Independently adjudicated long-term results of the device in treating these lesions are still indeterminate. We present 3-year results, with additional application of a flow diverter specific occlusion scale. METHODS: PREMIER (prospective study on embolization of intracranial aneurysms with pipeline embolization device) is a prospective, single-arm trial. Inclusion criteria were patients with unruptured wide-necked intracranial aneurysms ≤12 mm. Primary effectiveness (complete aneurysm occlusion) and safety (major neurologic event) endpoints were independently monitored and adjudicated. RESULTS: As per the protocol, of 141 patients treated with a PED, 25 (17.7%) required angiographic follow-up after the first year due to incomplete aneurysm occlusion. According to the Core Radiology Laboratory review, three (12%) of these patients progressed to complete occlusion, with an overall rate of complete aneurysm occlusion at 3 years of 83.3% (115/138). Further angiographic evaluation using the modified Cekirge-Saatci classification demonstrated that complete occlusion, neck residual, or aneurysm size reduction occurred in 97.1%. The overall combined safety endpoint at 3 years was 2.8% (4/141), with only one non-debilitating major event occurring after the first year. There was one case of aneurysm recurrence but no cases of delayed rupture in this series. CONCLUSIONS: The PED device presents as a safe and effective modality in treating small- and medium-sized intracranial aneurysms. The application of a flow diverter specific occlusion classification attested the long-term durability with higher rate of successful aneurysm occlusion and no documented aneurysm rupture. TRIAL REGISTRATION: NCT02186561.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.038

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.275
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations101
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of NeuroInterventional SurgerySame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207