MétaCan
Menu
Back to cohort
Record W4221071329 · doi:10.1016/j.jlr.2022.100204

A high-throughput platform for the rapid screening of vitamin D status by direct infusion-MS/MS

2022· article· en· W4221071329 on OpenAlexafffund
Erick Helmeczi, Eric Fries, Lauren M. Perry, Karen Choong, Katie O’Hearn, Dayre McNally, Philip Britz‐McKibbin

Bibliographic record

VenueJournal of Lipid Research · 2022
Typearticle
Languageen
FieldMedicine
TopicVitamin D Research Studies
Canadian institutionsUniversity of OttawaChildren's Hospital of Eastern OntarioMcMaster University
FundersInstitute of Population and Public HealthGenome CanadaCanadian Institutes of Health ResearchCanada Foundation for InnovationNatural Sciences and Engineering Research Council of CanadaMcMaster UniversityPhysicians' Services Incorporated Foundation
KeywordsCoefficient of variationChromatographyVitamin D and neurologyImmunoassayDetection limitMedicineInternal medicineChemistryImmunologyAntibody

Abstract

fetched live from OpenAlex

Vitamin D is an important fat-soluble prohormone with pleiotropic effects on human health, such as immunomodulation of the innate and adaptive immune system. There is an unmet clinical need for a rapid screening platform for 25-hydroxyvitamin D (25OH-D) determination without chromatographic separation that offers better precision and accuracy than immunoassays. Here, we introduce a high-throughput method for assessing vitamin D status from blood specimens based on direct infusion-MS/MS (DI-MS/MS) following click derivatization using 2-nitrosopyridine. We developed an optimized liquid-phase extraction protocol to minimize ion suppression when directly infusing serum or plasma extracts via a capillary electrophoresis system for quantitative determination of 25OH-D. Acceptable reproducibility (mean coefficient of variation = 10.9%, n = 412), recovery (mean = 102% at 15, 30, and 45 nmol/l), and linearity ( R 2 > 0.998) were achieved for 25OH-D with lower detection limits (limit of detection ∼1.2 nmol/l, S/N ∼ 3), greater throughput (∼3 min/sample), and less bias than a commercial chemiluminescence immunoassay prone to batch effects. There was mutual agreement in 25OH-D concentrations from reference blood samples measured by DI-MS/MS as compared with LC-MS/MS (mean bias = 7.8%, n = 18). We also demonstrate that this method could reduce immunoassay misclassification of vitamin D deficiency in a cohort of critically ill children ( n = 30). In conclusion, DI-MS/MS offers a viable alternative to LC-MS/MS for assessment of vitamin D status in support of large-scale studies in nutritional epidemiology as well as clinical trials to rapidly screen individual patients who may benefit from vitamin D supplementation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.387
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Lipid ResearchSame topicVitamin D Research StudiesFrench-language works237,207