MétaCan
Menu
Back to cohort
Record W4224088275 · doi:10.3390/tomography8020091

Noise-Based Image Harmonization Significantly Increases Repeatability and Reproducibility of Radiomics Features in PET Images: A Phantom Study

2022· article· en· W4224088275 on OpenAlexafffund
H. Keller, Tina Shek, Brandon Driscoll, Yiwen Xu, Brian Nghiem, Sadek A. Nehmeh, Milan Grkovski, C. Ross Schmidtlein, Mikalai M. Budzevich, Yoganand Balagurunathan, John J. Sunderland, Reinhard Beichel, Carlos Uribe, Ting‐Yim Lee, Fiona Li, David A. Jaffray, Ivan Yeung

Bibliographic record

VenueTomography · 2022
Typearticle
Languageen
FieldMedicine
TopicRadiomics and Machine Learning in Medical Imaging
Canadian institutionsWestern UniversityLawson Health Research InstituteBC Cancer AgencyUniversity Health NetworkUniversity of TorontoUniversity of British Columbia
FundersCanadian Institutes of Health ResearchNational Cancer InstituteNational Institutes of HealthOntario Institute for Cancer ResearchUniversity of IowaGeoffrey Beene Cancer Research CenterMemorial Sloan-Kettering Cancer Center
KeywordsRepeatabilityImaging phantomReproducibilityArtificial intelligenceScannerRobustness (evolution)Feature (linguistics)Pattern recognition (psychology)Noise (video)Image noiseIntraclass correlationComputer scienceComputer visionImage textureImage processingMathematicsImage (mathematics)Nuclear medicineStatisticsMedicine

Abstract

fetched live from OpenAlex

For multicenter clinical studies, characterizing the robustness of image-derived radiomics features is essential. Features calculated on PET images have been shown to be very sensitive to image noise. The purpose of this work was to investigate the efficacy of a relatively simple harmonization strategy on feature robustness and agreement. A purpose-built texture pattern phantom was scanned on 10 different PET scanners in 7 institutions with various different image acquisition and reconstruction protocols. An image harmonization technique based on equalizing a contrast-to-noise ratio was employed to generate a "harmonized" alongside a "standard" dataset for a reproducibility study. In addition, a repeatability study was performed with images from a single PET scanner of variable image noise, varying the binning time of the reconstruction. Feature agreement was measured using the intraclass correlation coefficient (ICC). In the repeatability study, 81/93 features had a lower ICC on the images with the highest image noise as compared to the images with the lowest image noise. Using the harmonized dataset significantly improved the feature agreement for five of the six investigated feature classes over the standard dataset. For three feature classes, high feature agreement corresponded with higher sensitivity to the different patterns, suggesting a way to select suitable features for predictive models.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.016
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.276
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueTomographySame topicRadiomics and Machine Learning in Medical ImagingFrench-language works237,207