MétaCan
Menu
Back to cohort
Record W4224230193 · doi:10.3390/s22082830

Towards Development of Specular Reflection Vascular Imaging

2022· article· en· W4224230193 on OpenAlexaff
Timothy Burton, Gennadi Saiko, Alexandre Douplik

Bibliographic record

VenueSensors · 2022
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsSt. Michael's HospitalToronto Metropolitan University
Fundersnot available
KeywordsSpecular reflectionSpecular highlightReflection (computer programming)Computer visionSIGNAL (programming language)Computer sciencePixelBlood flowWaveformArtificial intelligenceVisualizationRay tracing (physics)Medical imagingBiomedical engineeringOpticsAcousticsMedicineRadiologyPhysicsTelecommunications

Abstract

fetched live from OpenAlex

Specular reflection from tissue is typically considered as undesirable, and managed through device design. However, we believe that specular reflection is an untapped light-tissue interaction, which can be used for imaging subcutaneous blood flow. To illustrate the concept of subcutaneous blood flow visualization using specular reflection from the skin, we have developed a ray tracing for the neck and identified conditions under which useful data can be collected. Based on our model, we have developed a prototype Specular Reflection Vascular Imaging (SRVI) device and demonstrated its feasibility by imaging major neck vessels in a case study. The system consists of a video camera that captures a video from a target area illuminated by a rectangular LED source. We extracted the SRVI signal from 5 × 5 pixels areas (local SRVI signal). The correlations of local SRVIs to the SRVI extracted from all pixels in the target area do not appear to be randomly distributed, but rather form cohesive sub-regions with distinct boundaries. The obtained waveforms were compared with the ECG signal. Based on the time delays with respect to the ECG signal, as well as the waveforms themselves, the sub-regions can be attributed to the jugular vein and carotid artery. The proposed method, SRVI, has the potential to contribute to extraction of the diagnostic information that the jugular venous pulse can provide.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0020.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.311
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueSensorsSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207