MétaCan
Menu
Back to cohort
Record W4225257269 · doi:10.14740/jocmr4723

An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care

2022· article· en· W4225257269 on OpenAlexvenueno aff
Ismail Bekiroglu, Kwaku Owusu‐Bediako, Julie Rice‐Weimer, Joseph D. Tobias

Bibliographic record

VenueJournal of Clinical Medicine Research · 2022
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineBlood pressureCannulaMean arterial pressureAnesthesiaCohortDiastoleContinuous monitoringAdverse effectCardiologySurgeryInternal medicineHeart rate

Abstract

fetched live from OpenAlex

Background: In specific clinical scenarios or with patient comorbid conditions, continuous blood pressure (BP) monitoring may be required as it can be expected to provide superior physiologic monitoring to intermittent techniques. However, continuous BP monitoring requires an arterial cannula (AC) placement, which may be time-consuming, technically challenging, or associated with adverse events. Various noninvasive BP devices have been developed which provide a continuous BP reading. The current study evaluates the accuracy of a novel continuous BP device, the NICCI monitor (NM), in pediatric patients weighing 10 - 40 kg. Methods: The study cohort included pediatric patients weighing between 10 and 40 kg, scheduled for surgery for which placement of an AC was planned. Systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressure readings were captured from the AC and the NM every second during anesthetic care. Results: The study cohort included 24 pediatric patients undergoing major orthopedic, cardiac, and neurosurgical procedures. A total of 146,562 pairs of SBP, DBP, and MAP values from the AC and NC were analyzed. The absolute difference for the NM and the AC's SBP, DBP, and MAP values were 11 ± 9, 10 ± 7, and 10 ± 7 mm Hg, respectively. The difference between the BP values from the NM and the AC was ≤ 10 mm Hg for 57% of the SBP readings, 60% of the DBP readings, and 56% of the MAP readings. The bias was 4, 4, and 6 mm Hg for the SBP, DBP, and MAP, respectively. Conclusions: Although there were some technical limitations given patient size, potentially resulting in variation in accuracy, the NM provided a continuous noninvasive BP measurement within clinically useful limits during a significant portion of anesthetic care compared to values obtained from an AC. Ongoing modification of the technology to improve its application in pediatric patients will likely increase its accuracy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Direct model labels (unvalidated)

Per-model category and study-design labels from the labeling rounds. They are machine output, unvalidated, and the disagreement between models ships as data. No study design here is MEDLINE-validated yet.

Model armCategoriesStudy designConfidence
gemmano category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Bench or experimentallow
gptno category
Domain: not available · Genre: Empirical
About the Canadian research system: no · About a Canadian topic: no
Observationallow
models splitAgreement compares identical category sets and study designs across arms.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesResearch integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0180.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.003
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.092
GPT teacher head0.492
Teacher spread0.400 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Labeled directly by 2 models reading the full record.

The models applied no category: nothing in the taxonomy fit this work.

The models disagree on parts of this classification; every voice is preserved in the section at the end of the page.

Study designBench or experimental · Observational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical Medicine ResearchSame topicHemodynamic Monitoring and TherapyFrench-language works237,207