MétaCan
Menu
Back to cohort
Record W4225477716 · doi:10.1051/e3sconf/202234301004

Evaluation of mixed mode ventilation cooling energy saving potential in nZEB: A case study in Southern Italy

2022· article· en· W4225477716 on OpenAlexaff
Roberto Stasi, F. Ruggiero, Umberto Berardi

Bibliographic record

VenueE3S Web of Conferences · 2022
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsVentilation (architecture)HVACZero-energy buildingEnvironmental scienceEnergy consumptionEnergy recovery ventilationHeat pumpPrimary energyElectricityArchitectural engineeringMeteorologyCivil engineeringHeat exchangerEngineeringAir conditioningMechanical engineeringElectrical engineeringGeography

Abstract

fetched live from OpenAlex

In recent decades, reducing the energy demand of the building sector has become a major goal of global policies. Proper design of the building-plant system is hence strategic to achieve nearly zero energy building (NZEB) target. This paper reports the results of modeling the building-plant system of an NZEB in Southern Italy. The case study is a multi-family complex of eight dwellings located in Bari, in the Apulia region. The building project originates from the energy refurbishment of a former industrial shed that was demolished and rebuilt for residential use. The planned HVAC system foresees the combined use of primary ventilation with fan-coil units fed by two ground source heat pumps (GSHP) supplied by eight vertical probes. Three hybrid ventilation strategies have been compared to evaluate the potential cooling energy saving: the first one examines an earth-to-air heat exchanger (EAHX), the second one proposes night hybrid ventilation from 10 pm to 6 am, and the last considers the adoption of free cooling in mechanical ventilation. Economic and energy comparisons among these three approaches are reported. Using EAHX, the cooling consumption saving reached about 20.7% The use of night ventilation combined with MVS can reduce the cooling energy demand for 14.4%, while free cooling in MVS produces a less effective decrease in the electricity consumption for cooling of about 7.7%. All three strategies generate major benefits in the middle-season.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.042
Threshold uncertainty score0.083

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.256
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueE3S Web of ConferencesSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207