MétaCan
Menu
Back to cohort
Record W4231962943 · doi:10.32920/ryerson.14639040.v1

Numerical Heat Transfer Comparison Study of Hybrid and Nonhybrid Ground Source Heat Pump Systems

2021· preprint· en· W4231962943 on OpenAlexafffund
Nikola Kuzmic, Ying Lam E. Law, Seth B. Dworkin

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEnergy
TopicGeothermal Energy Systems and Applications
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsHeat pumpHVACSizingHeat transferFoulingAir source heat pumpsEnvironmental scienceAir conditioningEngineeringHeat exchangerMechanical engineeringMechanics

Abstract

fetched live from OpenAlex

Ground Source Heat Pump (GSHP) systems, if improperly designed may lead to overheating or overcooling of the ground. Good designs ensure properly balanced energy storage through adequately sizing ground-loops. Hybrid systems combine conventional Heating, Ventilating, and Air Conditioning (HVAC) with GSHPs in order to significantly reduce the high installation costs of GSHPs. The hybrid systems are designed in such a way that GSHPs provide the base building energy demands while the conventional HVAC is used only during the peak hours. In general, all buildings can be divided into two main categories: cooling dominant and heating dominant. If a building is cooling dominant, ground temperature increases with time and in heating dominant cases it decreases. A severe ground temperature increase/decrease is referred to as ‘ground fouling’ because it can render the GSHP inoperable, as temperature differences are required to maintain controlled heat flow. This paper compares long-term operation of hybrid and nonhybrid GSHP systems in order to investigate the effectiveness of hybridization at alleviating ‘ground fouling’. A homespun 2D finite-volume model is proposed to study heat transfer in ground coupled heat pump systems and is verified against an analytical solution as well as experimental data. Through simulation of different building types, it is demonstrated that hybridization has potential to reduce ‘ground fouling’ but only in limited cases for which a large portion of the energy demands is being met by the conventional HVAC.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.256
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicGeothermal Energy Systems and ApplicationsFrench-language works237,207