Locating and Repairing Casing Leaks With Tubing in Place—Ultrasonic Loggingand Pressure-Activated Sealant Methods
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
When operators are faced with issues involving casing leaks, a typical course of action is to pull the tubing and make efforts to identify and locate the source of the leak by logging or other mechanical means. If the leak source can be successfully located, a mechanical method is generally employed to patch the leaking casing. This methodology is time consuming and expensive.Locating casing leaks with the tubing in place using conventional logging techniques has historically been difficult. Where some tools, such as temperature tools, may provide an indication of an anomaly in annuli, the data may be subjective or the leak may be too small to measure. When active, a leak will produce a spectrum of sonic frequencies that may be either audible, ultrasonic or both. Ultrasonic energy will pass through steel but travels relatively short distances. A tool developed around these principles has been successful in accurately locating casing leaks behind tubing.Pressure-activated sealants have been used for a number of years to cure a wide variety of leaks in casing, tubing, control lines, and well heads as well as micro-annulus leaks in cement. For the purpose of repairing a casing leak behind tubing, the liquid sealant may be pumped into the annulus and displaced to the leak site. The liquid sealant will not polymerize until it is exposed to the differential pressure through the leak site. Knowing the leak rate, pressure and precise location of the leak aids in the selection of the sealant formulation and deployment method. This helps to reduce overall repair cost as well as increase the probability of a successful repair.This paper will describe the ultrasonic method of leak detection and the method of curing leaks with pressure activated sealant with tubing in place. Case histories will be presented where these methods were employed to repair casing leaks without removing the tubing.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it