Development of Waste Heat Fired Activated Carbon Ammonia Adsorption Chiller

2015· article· en· W4236364840 on OpenAlexvenueno aff
Mohammed Sadhikh, Jaice Skaria

Bibliographic record

VenueInternational Journal of Thermal and Environmental Engineering · 2015
Typearticle
Languageen
FieldEngineering
TopicAdsorption and Cooling Systems
Canadian institutionsnot available
Fundersnot available
KeywordsChillerRefrigerantWaste heatCoefficient of performanceCooling capacityEvaporatorCondenser (optics)AdsorptionRefrigerationEnvironmental scienceThermodynamicsProcess engineeringAbsorption refrigeratorWaste managementHeat pumpNuclear engineeringMaterials scienceHeat exchangerChemistryEngineeringPhysics

Abstract

fetched live from OpenAlex

Adsorption systems are promising alternative to the existing refrigeration systems in the wake of alarming energy crisis and potential danger due to the use of ozone depleting refrigerants. Sorption systems use thermal energy as its power source and solid adsorbent beds to adsorb and desorb a refrigerant to obtain the desired cooling effect. Solar energy, engine exhaust and low grade waste heat could be used to drive the sorption compressors. The use of non-ozone depleting refrigerant makes these systems environmentally benign. Adsorption refrigeration systems can meet the cooling requirement across a wide range of temperatures. These systems have minimal moving parts and hence they are free of noise, vibration and related problems. This paper will present the description, operation and simulated system characteristics for a 1000W adsorption chiller. The adsorption system performance factors such as coefficient of performance (COP), specific cooling power (SCP), and cycle time were predicted. Parameters such as the generation and adsorption temperature, condenser and evaporator temperature were varied to analyze the influence of the varied operating conditions. A two bed 1000 W capacity adsorption water chiller to chill water from 12 to 7 C was considered for the simulation. COP of the simulated system ranged between 0.3 to 0.4 and SCP from 90 to 180 W/kg AC respectively. The maximum value of cycle time obtained was 25 minutes when the generation outlet temperature was 180 oC.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.127
Threshold uncertainty score0.354

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.181
Teacher spread0.172 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Thermal and Environmental EngineeringSame topicAdsorption and Cooling SystemsFrench-language works237,207