MétaCan
Menu
Back to cohort
Record W4237516526 · doi:10.1109/nssmic.2003.1352315

CT acquisition using PET detectors and electronics

2003· article· en· W4237516526 on OpenAlexafffund
P. Bérard, Christian Pépin, D. Rouleau, J. Cadorette, Roger Lecomte

Bibliographic record

Venue2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) · 2003
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversité de Sherbrooke
FundersNational Institute for Materials ScienceNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsImaging phantomScintillatorDetectorPhoton countingImage resolutionMonochromatic colorNuclear medicinePhysicsOpticsMedicine

Abstract

fetched live from OpenAlex

The emergence of PET/CT multi-modality imaging has provided the ability to sequentially obtain anatomic and functional information using adjacent PET and CT scanners without having to move the patient. To avoid the need for successive PET and CT scans, we have investigated the possibility of acquiring both the anatomic and functional images using the same detection system, based on conventional PET detectors and electronics operated in photon counting mode. The detector consisted of a high-luminosity LSO scintillator individually coupled to an avalanche photodiode to enable low-energy X-ray detection at high-count rate. A simulator was set up to collect tomographic data using a monochromatic 60 keV source (/sup 241/Am) to irradiate a phantom made of tissue-equivalent materials. The measured spatial resolution with this non-optimized setup was nearly 1 mm, demonstrating the capability to provide fairly accurate anatomical localization in CT counting mode. The images obtained showed that the three main constituents of a biological body (bones, water and air) can be clearly identified with a dose significantly lower than with conventional CT operated in current mode. These preliminary results demonstrate the feasibility of dual-modality PET/CT imaging based on PET detectors and electronics, and confirm that substantial dose reduction would be possible by acquiring the CT image in photon counting mode.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.013
Threshold uncertainty score0.043

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0130.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.292
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2003
Admission routes2
Has abstractyes

Explore more

Same venue2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)Same topicMedical Imaging Techniques and ApplicationsFrench-language works237,207