MétaCan
Menu
← Back to cohort
Record W4238036774 · doi:10.32920/ryerson.14649060

Design and development of a catheter-based tunable device for percutaneous mitral repair through coronary sinus

2021· preprint· en· W4238036774 on OpenAlexaff
Ata Taghipour

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsPercutaneousMitral regurgitationCatheterCoronary sinusCardiologyMedicineCoronary artery diseaseCircumflexInternal medicineMitral valveBiomedical engineeringRadiologyArtery

Abstract

fetched live from OpenAlex

According to the American Heart Association, the cardiac disease accounts for over 800,000 deaths every year (1 of every 3 deaths) in the US alone. Mitral regurgitation, which occurs in 2% of the population, has become the dominant valvular disease contributing to the high death rate caused by cardiac disease. The existing percutaneous treatments of mitral regurgitation suffer from compression of left circumflex artery, limiting their performance and causing serious iatrogenic consequences. Moreover, they are not tunable resulting in limited functionality. In this thesis, a catheter-based tunable device is designed to be implanted inside the coronary sinus for improving mitral regurgitation grade while minimizing the applied force on the left circumflex artery. A comprehensive computed tomography scan image analysis and experiments are performed to extract the required information for the design of the device and its evaluation with FEM simulations. A new effective engagement mechanism for integrating the device with the steerable catheter is designed and tested through large-scale experiments. Additionally, a temperature insensitive force/torque sensor is designed for guiding and introducing the device. This sensor can also be used in other catheter-based devices such as cardiac ablation catheters. The sensing structure of the sensor and its sensing method are evaluated by FEM simulations and large-scale prototyping. The actual-scale prototype of the sensor is fabricated, and the experiments are performed for analyzing the static and dynamic response of the sensor and its temperature cross-sensitivity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.340
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicCardiac Valve Diseases and Treatments→French-language works237,207→