MétaCan
Menu
Back to cohort
Record W4244317314 · doi:10.5383/ijtee.14.02.004

Energy Rating for Residential Buildings in Amman

2017· article· en· W4244317314 on OpenAlexvenueno aff
Bashar R. Qawasmeh, Ahmed Al‐Salaymeh, Ma En, Sinem Sarı, Nadeen Elian, Nadeen Zahran

Bibliographic record

VenueInternational Journal of Thermal and Environmental Engineering · 2017
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsnot available
Fundersnot available
KeywordsApartmentEnvelope (radar)Degree (music)Environmental scienceEnergy (signal processing)Materials scienceMathematicsCivil engineeringEngineeringStatisticsPhysicsAcousticsTelecommunications

Abstract

fetched live from OpenAlex

d heating energy requirement has been calculated according to Jordanian codes, using Hourly Analysis Program (HAP) and degree-days method (DD). The energy rating which provides the necessary information about the energy performance of the residential buildings has been assessed. The assessment is based on the thermal envelope. The annual energy loads are calculated for different cases according to different parameters such as glass layers for windows, and direction of the apartment. Two main cases are considered in constructing the energy rating scale; the cases are two apartments (one directed to the right while the other is directed to the left) located in Marka, Amman, Jordan. The two apartments have the same area of 110 m2 and in the same building's floor. The different orientations have been considered for the apartments of 90, 180 and 270 degree clock wise rotations. Then, the heating and cooling loads are calculated for all orientations using single glass and double glass. The annual cooling and heating energy without rotation using degree-days method (DD): for case one are 123.8 kWh/m² (for single glass) and 112.8 kWh/m² (for double glass), and for case 2 are 125.9 kWh/m² (for single glass) and 114.6 kWh/m² (for double glass) at Tb=18.3 Ԩ for heating and Tb =24 Ԩ for cooling. These results are in good agreement with the HAP results. Finally, an energy rating scale was suggested for residential buildings in Amman.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.042
Threshold uncertainty score0.282

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.184
Teacher spread0.180 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Thermal and Environmental EngineeringSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207