MétaCan
Menu
Back to cohort
Record W4244786849 · doi:10.26434/chemrxiv.14249057

On-Chip Glucose Detection Based on Glucose Oxidase Encapsulated on a Platinum Modified Gold Microband Electrode

2021· preprint· en· W4244786849 on OpenAlexaff
Julia Madden, Colm Barrett, Fathima Laffir, Michael A. Thompson, Paul Galvin, Alan O’Riordan

Bibliographic record

VenueChemRxiv · 2021
Typepreprint
Languageen
FieldEngineering
TopicElectrochemical sensors and biosensors
Canadian institutionsUniversity of Toronto
FundersInsight SFI Research Centre for Data AnalyticsScience Foundation Ireland
KeywordsGlucose oxidaseLinear sweep voltammetryCyclic voltammetryBiosensorDielectric spectroscopyElectrodePlatinumMicrofabricationMaterials scienceAnalytical Chemistry (journal)VoltammetryChemistryElectrochemistryChromatographyNanotechnologyBiochemistryCatalysis

Abstract

fetched live from OpenAlex

We report a two-step electrodeposition process incorporating glucose oxidase onto a platinum- modified gold microband electrode with an o-phenylenediamine and ß-cyclodextrin mixture. The bare microband electrodes were fabricated on silicon using standard microfabrication methods i.e. lithography and etching techniques. The two-step electrode modification process was characterized using cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The enzymatic based microband biosensor exhibited a linear response to glucose from 2.5-15 mM using both linear sweep voltammetry and chronoamperometric measurements in buffer based solutions. The resulting miniaturized glucose sensor presented a number of advantages such as ease of use, fast response time, measuring within physiologically relevant glucose concentrations in addition to sensing in small sample volumes without the need for an external counter and reference electrode. The biosensor performance was tested in 30 µl volumes of undiluted fetal bovine serum. Whilst a reduction in signal was evident within 100 % serum samples, the sensor achieved linear glucose detection with increasing glucose concentrations (2-12 mM).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.056
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.198
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueChemRxivSame topicElectrochemical sensors and biosensorsFrench-language works237,207