MétaCan
Menu
Back to cohort
Record W4248940309 · doi:10.32920/ryerson.14651730

Visualisation of flow pattern and measurement of liquid distribution in a random packed column using electrical resistance tomography (ERT)

2021· preprint· en· W4248940309 on OpenAlexaff
Nazar Aoda

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicElectrical and Bioimpedance Tomography
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsVolumetric flow rateFlow (mathematics)Packed bedMechanicsMaterials scienceFlow velocitySuperficial velocityAnalytical Chemistry (journal)ChemistryPhysicsChromatography

Abstract

fetched live from OpenAlex

The aim of this research is to use Electrical Resistance Tomography technique (ERT) to measure factors that affect local mass transfer at various axial locations in a random packed column with diameter 0.3m and bed height 150cm filled with 2 cm plastic spheres. These factors are: liquid maldistribution, velocity profiles, and flow pattern. The system was designed to run in a trickling down-flow mode and a full liquid up-flow mode. Experiments were performed at flow rates of 3, 6, and 9 gpm (or 0.27 x 10⁻², 0.54 x 10⁻² and 0.8 x 10⁻² m³/m² s) and under normal operating conditions of 25C° and atmospheric pressure. The liquid maldistribution factors were measured via ERT technique and the conventional liquid collection method. Both measurements were conducted at various fluid flow rates at different bed heights. The results of ERT were in very good agreement with the conventional method. The standard deviation values were 17% and 21% at flow rates 3 and 6 gpm respectively. The numerical values of velocity for full liquid up flow at 3 gpm were 0.83cm/s, 1.2cm/s, 1.2 cm/s and 1.11 cm/s for different heights of 30, 60 and 90 cm respectively and the numerical values of velocity for trickle down flow at 3 gpm were 16.5 cm/s, 22.5 cm/s and 24 cm/ for different heights of 30, 60 and 90 cm respectively. The values of the liquid maldistribution factor for flow rate 3 gpm were 0.43 (30cm), 0.33(60cm) and 0.30 (90cm) and for flow rate 6 gpm were 0.33(30cm), 0.27(60cm) and 0.22 (90cm). By comparison with findings of many studies conducted on liquid distribution in packed bed column, a good agreement was observed on the relation of Mf and flow rates and bed heights.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.372
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.226
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same topicElectrical and Bioimpedance TomographyFrench-language works237,207