MétaCan
Menu
Back to cohort
Record W4252660823 · doi:10.3109/10929080701526872

Intraoperative cone-beam CT for image-guided tibial plateau fracture reduction

2007· article· en· W4252660823 on OpenAlexaff
Amal Khoury, J. H. Siewerdsen, Cari Whyne, Michael J. Daly, Hans J. Kreder, D Moseley, David A. Jaffray

Bibliographic record

VenueComputer Aided Surgery · 2007
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of TorontoOntario Institute for Cancer ResearchPrincess Margaret Cancer CentreUniversity Health NetworkSunnybrook Health Science Centre
FundersNational Cancer Institute
KeywordsFluoroscopyCone beam computed tomographyCadaveric spasmMedicineImage qualityReduction (mathematics)Nuclear medicineCone beam ctFlat panel detectorImage noiseRadiologyComputer scienceArtificial intelligenceDetectorComputed tomographySurgeryOpticsPhysicsMathematics

Abstract

fetched live from OpenAlex

Objectives: A mobile isocentric C-arm was modified in our laboratory in collaboration with Siemens Medical Solutions to include a large-area flat-panel detector providing multi-mode fluoroscopy and cone-beam CT (CBCT) imaging. This technology is an important advance over existing intraoperative imaging (e.g., Iso-C3D), offering superior image quality, increased field of view, higher spatial resolution, and soft-tissue visibility. The aim of this study was to assess the system's performance and image quality in tibial plateau (TP) fracture reconstruction.Methods: Three TP fractures were simulated in fresh-frozen cadaveric knees through combined axial loading and lateral impact. The fractures were reduced through a lateral approach and assessed by fluoroscopy. The reconstruction was then assessed using CBCT. If necessary, further reduction and localization of remaining displaced bone fragments was performed using CBCT images for guidance. CBCT image quality was assessed with respect to projection speed, dose and filtering technique.Results: CBCT imaging provided exquisite visualization of articular details, subtle fragment detection and localization, and confirmation of reduction and implant placement. After fluoroscopic images indicated successful initial reduction, CBCT imaging revealed areas of malalignment and displaced fragments. CBCT facilitated fragment localization and improved anatomic reduction. CBCT image noise increased gradually with reduced dose, but little difference in images resulted from increased projections. High-resolution reconstruction provided better delineation of plateau depressions.Conclusion: This study demonstrated a clear advantage of intraoperative CBCT over 2D fluoroscopy and Iso-C3D in TP fracture fixation. CBCT imaging provided benefits in fracture type diagnosis, localization of fracture fragments, and intraoperative 3D confirmation of anatomic reduction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.256
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueComputer Aided SurgerySame topicAdvanced X-ray and CT ImagingFrench-language works237,207