Safety and acute performance of paroxysmal and early persistent atrial fibrillation ablation using temperature-controlled, very high power, short duration catheter with a new radiofrequency generator
Bibliographic record
Abstract
Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Biosense Webster Inc. Background/Introduction The temperature-controlled contact force radiofrequency (RF) ablation catheter (QDM) has 6 thermocouples to maintain target catheter tip temperature and 3 tip microelectrodes for high local signal resolution. It has an enhanced irrigation profile to reduce char formation. Three prospective multicenter trials demonstrated safety and effectiveness of the QDM catheter using very high-power, short duration (vHPSD; 90W/4s), conventional power (CP; ≤50W) or combined modes. These studies were performed with an older RF generator. A new generator was developed to support the full suite of legacy, temperature controlled and multichannel ablation catheters, but has not yet been formally tested in a clinical setting. Purpose Evaluate safety and acute performance of the QDM catheter with the new 90W-enabled generator. Methods This prospective, multicenter study (4 Canadian sites) used vHPSD as primary mode for Pulmonary Vein (PV) isolation with overlapping 3mm lesion tags for anterior, inferior and roof of left atrium. Adjacent, non-overlapping lesions were used posteriorly to avoid esophageal heating. CP mode was used at operator discretion for thicker atrial tissue, touch ups, and non-PV triggers (Figure). Primary endpoint was confirmed entrance block in all PVs after adenosine and/or isoproterenol challenge. Acute procedural and safety data were assessed. Systematic char evaluation was performed. Results Effectiveness analysis included 38/40 subjects with mean 110-day follow up (mean age, 61.7 ± 9.5 years; 63.2% male). Hypertension (47.4%) and congestive heart failure (15.8%) were the most common comorbidities. Fourteen subjects were treated with version V0 of the generator, and 24 subjects were treated using version V1c which included further software adjustments to the power titration, and current response to optimize performance. Combination vHPSD/CP workflow was used for PV isolation in 28 (75.7%) subjects and vHPSD was used solely in 10. A non-study catheter was used in 1 subject during connectivity troubleshooting. Primary endpoint of entrance block confirmation was achieved in 37/38 subjects and in all 37 subjects treated with study catheter only. No incidences of char or device-related adverse events were reported. There were no noted differences in the endpoints evaluated between the V0 and V1c groups. Median (Q1/Q3) RF application times for ablating PVs was 13.0 min (9.0/16.0) for the entire cohort. Median (Q1/Q3) time to achieve PV isolation in vHPSD-only group was 9 (7/12) min, and 14 (11/18) min, respectively. Conclusion(s) Consistent with data from prior 3 clinical studies, QDM catheter with the new 90W-enabled generator demonstrated the acute safety and effectiveness of temperature-controlled AF ablation with short PV ablation time and no char observed.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".