MétaCan
Menu
Back to cohort
Record W4281609148 · doi:10.1007/s00216-022-04146-9

Low-level 40Ca determinations using nitrous oxide with reaction cell inductively coupled plasma–tandem mass spectrometry

2022· article· en· W4281609148 on OpenAlexaff
Shaun T. Lancaster, Thomas Prohaska, Johanna Irrgeher

Bibliographic record

VenueAnalytical and Bioanalytical Chemistry · 2022
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of Calgary
FundersEuropean Metrology Programme for Innovation and ResearchHorizon 2020 Framework ProgrammeEuropean Commission
KeywordsChemistryInductively coupled plasma mass spectrometryIsobaric processDetection limitAnalytical Chemistry (journal)AnalyteInductively coupled plasmaMass spectrometryArgonMagnesiumMatrix (chemical analysis)ChromatographyPlasma

Abstract

fetched live from OpenAlex

Abstract In inductively coupled plasma mass spectrometry, the most abundant Ca isotope (40Ca) suffers from isobaric interference with argon, hindering the potential for low detection limits of Ca. A powerful approach is to remove the interference by using a reaction gas in a reaction cell. Ammonia (NH3) has proven to be an effective reaction gas by process of a charge transfer reaction. However, NH3 is highly corrosive and toxic and cannot remove isobaric 40 K. Therefore, this work proposes the use of nitrous oxide (N2O) to mass shift the target analyte 40Ca to 40Ca16O+ as a non-corrosive and non-toxic alternative. Instrument performance testing demonstrated that N2O was capable of reaching equivalent detection limits (0.015 ng g−1) and background equivalence concentrations (0.041 ng g−1) to that of NH3 and limited by the blank only. Further investigation of matrix interferences with synthetic standards highlighted that the N2O approach supports the separation of potassium (K) and magnesium (Mg)–based interferences at tested concentrations of more than 600 times and almost 800 times higher than Ca respectively, whereas NH3 was found to only support the removal of Mg. This work highlights a clear advantage of N2O for low-level Ca determinations with high matrix loads, as well as compatibility with other instrumentation sensitive to corrosion that supports reaction cell technology. Graphical abstract

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.249
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical and Bioanalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207