MétaCan
Menu
Back to cohort
Record W4281756023 · doi:10.4187/respcare.10014

Monitoring of Heated Wire Humidifier Hygrometric Performances With Heater Plate Temperature

2022· article· en· W4281756023 on OpenAlexaff
François Lellouche, Serge Simard, Pierre-Alexandre Bouchard

Bibliographic record

VenueRespiratory Care · 2022
Typearticle
Languageen
FieldMedicine
TopicNosocomial Infections in ICU
Canadian institutionsInstitut universitaire de cardiologie et de pneumologie de Québec
Fundersnot available
KeywordsHumidifiersHumidityRelative humidityMedicineVentilation (architecture)Environmental chamberMaterials scienceComposite materialEnvironmental scienceMeteorologyChemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Under-humidification and associated complications may occur with heated humidifiers. Hygrometric performances of heated wire humidifiers are reduced by high ambient and high outlet ventilator temperatures. Currently, there is no reliable monitoring tool to evaluate humidification performances of heated wire humidifiers in the daily practice. We sought to demonstrate the relation between humidity delivered by heated wire humidifiers and different parameters that could be used to monitor humidity of gas delivered to subjects. METHODS: On a bench test, we measured heater plate temperature, inlet chamber temperature, and delivered humidity with MR850 system. Temperature displayed on the humidifier was also recorded. The measurements were performed at different ambient temperatures and five minute ventilation levels (5, 7.5, 10, 12.5, 15 L/min). Inlet chamber temperatures varied from 20–40°C. In each condition, hygrometric measurements with the psychrometric method were performed at steady state. RESULTS: We performed 279 measurements at steady state including all conditions. We found a good correlation between heater plate temperature and absolute humidity delivered (R 2 = 0.82). This relationship was hardly affected by ambient temperature, but minute ventilation had more effect. For different minute ventilations, the correlation between heater plate temperature and absolute humidity delivered was very good with coefficient of determination R 2 from 0.87–0.98. Heater plate temperature > 62°C was a good predictor of absolute humidity delivered > 30 mg H 2 O/L (area under the curve = 0.96, sensibility 79%, specificity 94%). No correlation existed between humidity delivered and the outlet chamber temperature (displayed on the humidifier). CONCLUSIONS: In this bench study, we have shown a good correlation between heater plate temperature and humidity delivered with a heated wire humidifier. This means that a “hidden” hygrometer is built into the heated wire humidifier. Heater plate temperature should be used as a surrogate of humidity to improve the humidification monitoring.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.482
Threshold uncertainty score0.547

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.282
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueRespiratory CareSame topicNosocomial Infections in ICUFrench-language works237,207