MétaCan
Menu
Back to cohort

Differences in Prognostic Value of Myocardial Perfusion Single-Photon Emission Computed Tomography Using High-Efficiency Solid-State Detector Between Men and Women in a Large International Multicenter Study

2022· article· en· W4283267805 on OpenAlexaff
Balaji Tamarappoo, Yuka Otaki, Tali Sharir, Lien-Hsin Hu, Heidi Gransar, Andrew J. Einstein, Mathews B. Fish, Terrence D. Ruddy, Philipp A. Kaufmann, Albert J. Sinusas, Edward J. Miller, Timothy M. Bateman, Sharmila Dorbala, Marcelo F. Di Carli, Evann Eisenberg, Joanna X. Liang, Damini Dey, Daniel S. Berman, Piotr J. Slomka

Bibliographic record

VenueCirculation Cardiovascular Imaging · 2022
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Ottawa
FundersNational Center for Advancing Translational SciencesNational Heart, Lung, and Blood InstituteNational Institutes of HealthDr. Miriam and Sheldon G. Adelson Medical Research Foundation
KeywordsMedicinePerfusionSingle-photon emission computed tomographyMulticenter studyComputed tomographyRadiologyMyocardial perfusion imagingMulticenter trialNuclear medicineDetectorPositron emission tomographyEmission computed tomographyInternal medicineOpticsRandomized controlled trial

Abstract

fetched live from OpenAlex

Background: Semiquantitative assessment of stress myocardial perfusion defect has been shown to have greater prognostic value for prediction of major adverse cardiac events (MACE) in women compared with men in single-center studies with conventional single-photon emission computed tomography (SPECT) cameras. We evaluated sex-specific difference in the prognostic value of automated quantification of ischemic total perfusion defect (ITPD) and the interaction between sex and ITPD using high-efficiency SPECT cameras with solid-state detectors in an international multicenter imaging registry (REFINE SPECT [Registry of Fast Myocardial Perfusion Imaging With Next-Generation SPECT]). Methods: Rest and exercise or pharmacological stress SPECT myocardial perfusion imaging were performed in 17 833 patients from 5 centers. MACE was defined as the first occurrence of death or myocardial infarction. Total perfusion defect (TPD) at rest, stress, and ejection fraction were quantified automatically by software. ITPD was given by stressTPD-restTPD. Cox proportional hazards model was used to evaluate the association between ITPD versus MACE-free survival and expressed as a hazard ratio. Results: In 10614 men and 7219 women, with a median follow-up of 4.75 years (interquartile range, 3.7–6.1), there were 1709 MACE. In a multivariable Cox model, after adjusting for revascularization and other confounding variables, ITPD was associated with MACE (hazard ratio, 1.08 [95% CI, 1.05–1.1]; P <0.001). There was an interaction between ITPD and sex ( P <0.001); predicted survival for ITPD<5% was worse among men compared to women, whereas survival among women was worse than men for ITPD≥5%, P <0.001. Conclusions: In the international, multicenter REFINE SPECT registry, moderate and severe ischemia as quantified by ITPD from high-efficiency SPECT is associated with a worse prognosis in women compared with men.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.115
Threshold uncertainty score0.926

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.256
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Cardiovascular ImagingSame topicCardiac Imaging and DiagnosticsFrench-language works237,207