Conflicting Aims and Values in the Application of Smart Sensors in Geriatric Rehabilitation: Ethical Analysis

2022· article· en· W4283312936 on OpenAlexvenueno aff
Christopher Predel, Cristian Timmermann, Frank Ursin, Marcin Orzechowski, Timo Ropinski, Florian Steger

Bibliographic record

VenueJMIR mhealth and uhealth · 2022
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsnot available
FundersBundesministerium für Gesundheit
KeywordsBeneficenceAutonomyRehabilitationEconomic JusticeRelevance (law)mHealthApplied psychologyComputer scienceQuality (philosophy)PsychologyMedicineEngineering ethicsNursingEngineeringPhysical therapyPsychological intervention

Abstract

fetched live from OpenAlex

BACKGROUND: Smart sensors have been developed as diagnostic tools for rehabilitation to cover an increasing number of geriatric patients. They promise to enable an objective assessment of complex movement patterns. OBJECTIVE: This research aimed to identify and analyze the conflicting ethical values associated with smart sensors in geriatric rehabilitation and provide ethical guidance on the best use of smart sensors to all stakeholders, including technology developers, health professionals, patients, and health authorities. METHODS: On the basis of a systematic literature search of the scientific databases PubMed and ScienceDirect, we conducted a qualitative document analysis to identify evidence-based practical implications of ethical relevance. We included 33 articles in the analysis. The practical implications were extracted inductively. Finally, we carried out an ethical analysis based on the 4 principles of biomedical ethics: autonomy, beneficence, nonmaleficence, and justice. The results are reported in categories based on these 4 principles. RESULTS: We identified 8 conflicting aims for using smart sensors. Gains in autonomy come at the cost of patient privacy. Smart sensors at home increase the independence of patients but may reduce social interactions. Independent measurements performed by patients may result in lower diagnostic accuracy. Although smart sensors could provide cost-effective and high-quality diagnostics for most patients, minorities could end up with suboptimal treatment owing to their underrepresentation in training data and studies. This could lead to algorithmic biases that would not be recognized by medical professionals when treating patients. CONCLUSIONS: The application of smart sensors has the potential to improve the rehabilitation of geriatric patients in several ways. It is important that patients do not have to choose between autonomy and privacy and are well informed about the insights that can be gained from the data. Smart sensors should support and not replace interactions with medical professionals. Patients and medical professionals should be educated about the correct application and the limitations of smart sensors. Smart sensors should include an adequate representation of minorities in their training data and should be covered by health insurance to guarantee fair access.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.245
Threshold uncertainty score0.251

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.342
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJMIR mhealth and uhealthSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207