MétaCan
Menu
Back to cohort
Record W4283388481 · doi:10.1111/trf.16974

Cold‐stored platelets are effective in an in vitro model of massive transfusion protocol assessed by rotational thromboelastometry

2022· article· en· W4283388481 on OpenAlexafffund
Han Qi Zhao, Katherine Serrano, Brankica Culibrk, Zhongming Chen, Dana V. Devine

Bibliographic record

VenueTransfusion · 2022
Typearticle
Languageen
FieldMedicine
TopicTrauma, Hemostasis, Coagulopathy, Resuscitation
Canadian institutionsCanadian Blood ServicesUniversity of British Columbia
FundersCanadian Blood ServicesBurroughs Wellcome Fund
KeywordsThromboelastometryMedicinePlateletWhole bloodHyperfibrinolysisHemostasisThromboelastographyPlatelet transfusionHematocritAnesthesiaBlood transfusionBlood productSurgeryCoagulopathyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Platelets are a key component of massive transfusion in treating actively bleeding patients. While optimized for prophylactic transfusions, the effectiveness of the current standard room temperature stored platelets (RPs) in treating actively bleeding patients is not clear. Cold-stored platelets (CPs) have been shown to have superior hemostatic functions and the potential to extend shelf life. In this study, we explored the effect of using CPs versus RPs in an in vitro transfusion model based on the massive transfusion protocol. STUDY DESIGN AND METHODS: RPs or CPs were combined with RBCs and plasma in a 1:1:1 volume ratio to make transfusion packages. Whole blood was collected and then either diluted to 20% hematocrit or mixed with tPA (8.8 μg/ml). By volume, 70% of transfusion package was mixed with 30% whole blood to simulate massive transfusions and analyzed by rotational thromboelastometry. Transfusion package supernatant was analyzed for PAI-1 activity as well. RESULTS: Both transfusion packages restored the clot characteristics of hemodiluted or hyperfibrinolytic whole blood. Specifically, only transfusion packages made with CPs significantly reduced the maximum clot lysis of hyperfibrinolytic whole blood. PAI-1 activity in CPs transfusion packages were also significantly higher. DISCUSSION: Transfusion packages containing cold-stored platelets may be able to restore the blood hemostatic profile of bleeding patients. In addition, transfusion packages made from CPs may provide additional benefit of resisting hyperfibrinolysis in bleeding patients. In trauma where post-transfusion platelet recovery is less of a concern, CPs are a viable option to restore hemostasis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.261
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.303
Teacher spread0.283 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueTransfusionSame topicTrauma, Hemostasis, Coagulopathy, ResuscitationFrench-language works237,207