MétaCan
Menu
Back to cohort
Record W4283823441 · doi:10.1103/physrevd.106.092001

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

2022· article· en· W4283823441 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenuePhysical review. D/Physical review. D. · 2022
Typearticle
Languageen
FieldPhysics and Astronomy
TopicParticle Detector Development and Performance
Canadian institutionsSnolab
FundersH2020 European Research CouncilLawrence Berkeley National LaboratoryU.S. Department of EnergyEuropean CommissionAgencia Estatal de InvestigaciónOffice of ScienceKavli FoundationBlond McIndoe Research FoundationNational Science FoundationUniversity of WashingtonAgencia Nacional de Promoción Científica y TecnológicaSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungUniversity of Chicago
KeywordsPhysicsCompton scatteringMonte Carlo methodElectronScatteringIonizationSiliconAtomic physicsSpectroscopyElectron scatteringComputational physicsOpticsNuclear physicsIonOptoelectronics

Abstract

fetched live from OpenAlex

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(10\text{ }\text{ }\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\ensuremath{\gamma}$ rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23 eV. A skipper charge-coupled device with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}\text{Am}$ $\ensuremath{\gamma}$-ray source over several months. Features associated with the silicon K-, ${\mathrm{L}}_{1}$-, and ${\mathrm{L}}_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100 eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5 keV. The data are in better agreement with ab initio calculations originally developed for x-ray absorption spectroscopy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.281
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.362
Teacher spread0.342 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it