MétaCan
Menu
Back to cohort
Record W4284881337 · doi:10.1109/tuffc.2022.3189338

Fine Pitch Flexible Printed Circuit Board Patterning for Miniaturized Endoscopic MicroUltrasound Arrays

2022· article· en· W4284881337 on OpenAlexafffund
Carlos-Felipe Roa, Nidhi Singh, Emmanuel Chérin, Jianhua Yin, Aaron Boyes, F. Stuart Foster, Christine Démoré

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2022
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Bio-sensing Technologies
Canadian institutionsSunnybrook HospitalUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaTerry Fox Research Institute
KeywordsMaterials sciencePrinted circuit boardFabricationLaser ablationOptoelectronicsFootprintPolyimideElectrodeComputer scienceLaserElectrical engineeringNanotechnologyOpticsEngineeringPhysics

Abstract

fetched live from OpenAlex

Microultrasound (micro-US) has become an invaluable tool for preclinical research and in emerging applications in clinical diagnosis and treatment guidance. Several such applications can benefit from arrays with a small footprint and endoscopic form factor. However, critical challenges arise in making electrical connections to array elements in such spatial constraints. In this work, we describe a method to pattern a high-density flexible circuit cabling on a copper-on polyimide film, using laser ablation of a polymer resist and wet etching, and then demonstrate a connection to a micro-US array. We investigate laser ablation process parameters and evaluate the ability to consistently pattern continuous copper traces. A minimum 30- [Formula: see text] pitch was achieved with 5- [Formula: see text]-wide electrode lines, and continuity of a 5-m-long trace is demonstrated. A flexible circuit with 30-mm-long traces with 30- [Formula: see text] line and 30- [Formula: see text] space before fan-out was fabricated to connect in an interleaved manner to a 32-element array with 30- [Formula: see text] element pitch. Metal deposition and laser ablation were used to connect and pattern the element electrodes to the copper traces of the flexible circuit. Electrical and acoustic measurements show good yield and consistent impedance across channels. Element pulse-echo tests demonstrated device functionality; the two-way pulse had 43-MHz center frequency and 40% fractional bandwidth (-6 dB). The proposed manufacturing methods facilitate the prototyping and fabrication of flexible endoscopic or small-footprint micro-US devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.205
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicMicrofluidic and Bio-sensing TechnologiesFrench-language works237,207